En
gl
is
h (
G
B)
66
9.14 Hotkeys / info keys
The following important displays and functions of the DDI 209 can be accessed quickly using button
combinations (hotkeys).
Service functions
Display functions in batch and timer operation
Other display functions
Function
Operating state of the
pump
Activate function /
display
Deactivate function /
display
Deaerate.
In "Run", "Stop" or
"Menu/Info" mode.
Press the "Start/Stop"
button for at least
1 second.
Release the "Start/Stop"
button.
Move back the
diaphragm for
servicing.
The pump must be in
"Stop" mode.
Simultaneously press the
"Up" and "Down" buttons.
—
Boot function.
The pump is
disconnected from the
power supply.
Simultaneously press the
"Up" and "Down" buttons
while switching on the
power supply.
—
Delete the total dosing
capacity.
In "Run" mode.
Press the "Menu/Info"
button for 5 seconds.
—
Display / function
Operating state of the
pump
Activate function /
display
Deactivate function /
display
Display the batch
quantity already dosed
since start of the batch.
During the batch dosing
in batch or timer
operation.
Press the "Down" button.
Release the "Down"
button.
Display total batch
quantity.
Press the "Up" button.
Release the "Up" button.
Display the time that
has already elapsed.
During pause times in
timer operation.
Press the "Down" button.
Release the "Down"
button.
Display the total time.
Press the "Up" button.
Release the "Up" button.
Display / function
Operating state of the
pump
Activate function /
display
Deactivate function /
display
Display the total dosing
capacity.
In "Run" mode.
Press the "Menu/Info"
button.
Display automatically
jumps back after
5 seconds.
Display the input
current.
In "Analog" mode
(0-20 mA / 4-20 mA).
Press the "Down" button.