Stop/start of pump during batch dosing
To stop the pump,
•
press the "Start/Stop" button, or
•
actuate remote on/off.
To restart the pump,
•
press the "Start/Stop" button.
– The preset batch cycle continues.
– For the "Contact" timer, an external contact
signal must also be received.
Deactivating the batch function
1. Open the second function level.
2. Repeatedly press the "Menu/Info" button.
– "ON B" appears in the display.
3. Press the "Up" button.
– "OFF B" appears in the display.
– The batch function is deactivated.
9.12 Timer menu / timer mode
In timer mode, a defined batch quantity is dosed with
a defined dosing flow. The first dosing starts after the
start time t
1
has elapsed. Batch dosing is then
repeated after the repetition time t
2
has elapsed until
the user stops the process by pressing the
"Start/Stop" button or with remote off.
•
Input range for the batch quantity:
0.0-999.9 ml / 1.00-99.99 l.
•
Input range for the times t
1
and t
2
:
1 min. < t
1
< 999 h / 1 min. < t
2
< 999 h.
Input: hh:mm.
Fig. 66
Timer mode
Timer mode is controlled at the first and second
function levels.
•
The batch quantity and times t
1
and t
2
are set in
the second function level.
•
Timer mode is enabled in the first function level.
TM
03
66
16
45
06
Batch 1
Batch 2
Batch n
Dosing
Dosing
Dosing
Start time t
1
Repetition time t
2
Repetition time t
2
Caution
Risk of dosing errors!
If repetition time t
2
is not long enough
to dose the batch quantity at the set
dosing flow within this time, the pump
continues dosing until the current
batch quantity is finished. The pump is
then stopped and the next batch
dosing is triggered after the next
repetition time.
Batch dosing in timer mode may be
insufficiently or excessively triggered
in the event of an error if the
pump/system is not monitored.
The system must be protected
redundantly.