English (GB)
41
9.5 Second function level
9.5.1 Opening / exiting the second function level
Open the second function level
•
to set the access code,
•
to enable or disable functions such as Flow
Monitor or memory,
•
to enter settings for operating modes such as
batch mode,
•
to display the total number of operating hours
and total dosing capacity,
•
to carry out a calibration, or
•
to modify the assignment between the current
input/output and dosing rate.
This function level can only be opened when the
pump is stopped (LED lights up red).
9.5.2 Setting the access code
The access code is used to protect the pump against
unintentional/unauthorised access to pump settings.
The default setting is 111. Code 111 gives access to
all settings described in sections
9.4 First function
level
and
9.5 Second function level
.
1. Press the "Start/Stop" button while the pump is
running (LED lights up green).
– The pump is stopped (LED lights up red).
2. Press and hold down the "Menu/Info" button for
3 seconds.
– The second function level is opened.
– The input arrow appears in the display.
– "C:111" (default setting is "111") or a
user-defined code appears in the display.
3. Use the "Up" and "Down" buttons to set the code
in the range between 1 and 999.
Code 111 is required to open the second function
level.
Note
The "Start/Stop" button for stopping
the pump is active with any code.