En
gl
is
h (
G
B)
48
Fig. 46
Opening / exiting the service level
1. Navigate in the service level by repeatedly
pressing the "Menu/Info" button.
2. Use the "Up" and "Down" buttons to modify the
switch assignment in the relevant menu.
3. Press the "Menu/Info" button for 10 seconds to
open the pump type selection.
4. Press the "Start/Stop" button
– to confirm the new settings
– to exit the service level
– to open the first function level.
TM
03 66
20 450
6
Stop
+
Menu
Info
Down
Stop
Start
Up
Menu
Info
Stop
Start
Stop
Start
Menu
Info
Pump not connected to power supply
LED alternately flashes red and green
LED lights up yellow
Service level
1. Relay function (stroke / pre-empty / pulse selection)
2. Relay output, NO/NC (stroke / pre-empty / pulse)
3. Pre-empty signal, NO/NC input
4. Empty signal, NO/NC input
5. Error signal, NO/NC output
6. Remote off, NO/NC input
7. Locking "run" on/off
P. CAL on/off
St: 60
- unit [l/h] / [gph]
Keep pressed for approx. 10 seconds
Keep pressed when switching on
Pump type
FE: 7