6.1.4 Remote on/off / contact input / current input
Socket 4
For the remote on/off input and contact input or
current input.
If the remote on/off and contact inputs are to be used
at the same time, wire 1 is assigned twice.
6.1.5 Empty signal only / pre-empty and empty signal
Socket 5
For the empty signal only or pre-empty and empty
signal input.
The suction lines with empty signal or pre-empty and
empty signal are pre-assembled with a plug for
socket 5.
Caution
For the connection of one cable, use a
plug adapter with simple cable entry,
for the connection of two cables, use a
plug adapter with double cable entry,
otherwise the protection will be lost!
Socket 4
Cable
Used for
Pin
Assignment
Wire colour
Remote on/off
input
Contact input
+/– current
input
1
GND
Brown
x
x
–
2
Current input
White
+
3
Remote on/off input
Blue
x
4
Contact input
Black
x
Socket 5
Used for
Pin
Assignment
Empty signal
Pre-empty signal
1
Empty signal
x
2
GND
x
x
3
Pre-empty signal
x