Installation
40 | 76
5.3.4
Inputs and outputs of the control unit
The control unit features a voltage-free input and output. These are configured in the installer
level (refer to chapter 4.5).
No.
Description
No.
Description
1
Programmable input DigIN
3
Voltage-free fault signal contact Pot.f.S. (No)
max. 230 V/max. 1 A
2
Programmable output Prog.Out
max. 230 V/max. 1 A
► Use the following connection cables for connecting to the programmable input or
voltage-free output of the control unit:
● Flexible cables of quality H03xx F 2x0.5 mm² or comparable for connecting the
programmable input (no. 1), because only voltage-free contacts are allowed to be
connected.
● Flexible cables of quality H05xx F 2x0.75 mm² or comparable for connecting the
voltage-free output (no. 2), because loads operated with mains voltage are allowed
to be connected.