Control unit
24 | 76
Menu items
Settings/remarks
Search for
reference
position
regeneration
valve
Exchanger tank 1
0 - Factory-setting
1 - Carry out function.
Exchanger 2
0 - Factory-setting
1 - Carry out function.
Move to reference position of the selected exchanger. Ongoing
regenerations are aborted. After completion, the factory-setting is
activated again.
Fill brine tank
operating
water volume
Deactivated - Factory-setting
Activated - Carry out function.
Fill the brine tank to a minimum water level (e.g. after cleaning the brine
tank). After completion, the factory-setting is activated again.
Start test
regeneration
0 - Factory-setting
1 - Carry out function.
Both exchangers are regenerated one after the other for test purposes
with shortened step times/quantities. After completion, the factory-setting
is activated again.
Select
regeneration
time
Automatic
Factory-setting
Fixed
Programming of 1 - 3 fixed regeneration times.
Regeneration only takes place, if required.