OM-CBE-10G
Installation
D. Anchor restraining cable bracket to a secure structure. One of the preferred
locations is on the concrete floor using anchor bolts (not provided) as shown
in photo on left.
4. Water Connection(s)
Install a check valve to prevent back flow in the incoming cold water line, as
required by local plumbing codes. Water pressure in the line should be between
30 and 60 PSI. If pressure is above 60 PSI, a pressure regulator will be needed.
These pressures will provide the 1.5 gallons per minute required for proper
steamer function.
A
¾
inch female NH connector (garden hose type) is used to attach the water
supply to each inlet valve. Two (2) supply connections are required for each unit.
One must be treated water (see water treatment section for requirements) and the
other may be untreated water.
Minimum inside diameter of the water feed line
is ½ inch. Use a washer in the hose connection.
Do not allow the connection
to leak, no matter how slowly. Do not over-tighten hose connections.
COLD WATER PRESSURE 30 - 60 PSI.
SEE PAGE
6
FOR WATER TREATMENT REQUIREMENTS.
This equipment is to be installed to comply with the basic plumbing code of the
Building Officials and Code Administrators International, Inc. (BOCA) and the Food
Service Sanitation Manual of the Food and Drug Administration (FDA).
NOTE:
Local code may also require an approved back flow prevention device.
5. Drain Connection
Preferred installation for proper operation is to pitch the unit slightly to the rear
(maximum
¼
inch)
. Do not pitch the unit’s floor towards the front.
There must be a free air gap between the end of the hose and the building drain. The
free air gap should be as close as possible to the unit drain. There must also be no
other elbows or restrictions between the unit drain and the free air gap.
Install the drain line with a constant downward pitch.
CAUTION
DO NOT USE PLASTIC PIPE. DRAIN MUST BE
RATED FOR BOILING WATER.
WARNING
DO NOT CONNECT THE DRAIN DIRECTLY TO
A BUILDING DRAIN. BLOCKING THE DRAIN IS
HAZARDOUS.
IMPROPER DRAIN LINE CONNECTION
BUILDING DRAIN
WATER TRAP
BUILDING DRAIN
AIR GAP