Sequence of Operation

1.   Preheating

 

When  the  power  switch  is  turned  on  the  burners  light  and  raises  the  cavity 

temperature to 200°F (the set point). No cooking mode has been selected and the 

display shows SELECT MODE on the first line and PREHEAT on the second line.

 

When the power switch is turned on from a cold start the unit turns on the center 

burner first and the cavity fan is off to allow the flue to heat gradually. After a few 

minutes all three burners will light.

 

When  the  temperature  rises  above  180°F  (20

°

F  below  the  set  point)  PREHEAT 

disappears from the display. The fan is allowed to operate at the selected speed. 

The temperature continues to rise to the set point at which time the burners will 

cycle on and off to keep it there.  At any time the user may select any cooking 

mode. However, if steam or combo modes are selected water will not enter the 

reservoirs until after the unit is heated.

2.  Flame-out detection

 

When the oven is started the cavity temperature should rise above 135

°

 in ten 

minutes.  If the burner didn’t start or has gone out the temperature at that time will 

be too low. The message “Burner not on. Relight” will be displayed and the oven 

will turn off. Follow the RE-LIGHT instructions.

3.  Ready indication

 

The ready condition is satisfied (the oven is ready) when the set cavity temperature 

is reached. In the idle condition (no cooking mode selected) the set point is 200

°

F. 

In steam mode it is set to generate steam. In combo and oven modes it is set 

by  the  user. When  the  oven  is  not  ready,  the  word  PREHEAT  is  displayed  and 

the  temperature  display  flashes.  Once  the  oven  comes  up  to  ready  PREHEAT 

disappears and the temperature display stops flashing. If the door is opened and 

the oven is loaded with cold food the cavity temperature will fall. However, since 

the ready condition has already been met the temperature display will not flash.

 

If the cooking mode is changed then the temperature display will resume flashing 

if  the  current  cavity  temperature  is  more  than  20

°

F  below  the  new  set  point, 

that is, the oven is not ready. Once ready state is achieved with the new settings 

the flashing will stop. The same sequence occurs if the temperature setting is 

changed.

4.  Water level

 

If combo or steam mode is selected one or more of the reservoirs will fill with 

water (after the unit is heated). There are two water level sensor probes, one for 

the center reservoir and one for the right reservoir. When the water level drops 

below a sensor probe (boils off) the associated water valve opens and refills the 

reservoir. Whenever a fill or drain valve is first opened a timer controls the fill and 

drain times. If the water level has not changed when this timer finishes an error 

message is displayed telling which valve (fill or drain) in which reservoir (1 or 2)

took too long to change.  If it takes too long to fill or drain a reservoir it could mean 

that the sensor probe is contaminated and should be cleaned. Fill timeout could 

also mean that the water pressure is very low or the main water valve is turned 

off. Drain timeout could mean that the drain is plugged and should be cleaned. 

Содержание (2) CBE-10G

Страница 1: ...Improper installation adjustment alteration service or maintenance can cause property damage injury or death Read the installation operating and maintenance instructions thoroughly before installing o...

Страница 2: ...EANING THE OUTSIDE OF THE UNIT DISCONNECT THE ELECTRIC POWER SUPPLY KEEP WATER AND CLEANING SOLUTIONS OUT OF CONTROLS AND ELECTRICAL COMPONENTS NEVER HOSE OR STEAM CLEAN ANY PART OF THE UNIT WARNING A...

Страница 3: ...page 14 16 Sequence of Operation page 17 18 Maintenance page 19 Cleaning page 20 21 Service Log page 22 NATIONAL FIRE PROTECTION ASSOCIATION 60 Batterymarch Park Quincy Massachusetts 02269 NFPA 70 Th...

Страница 4: ...d The optional stand must have casters Optional stands are available for single and double stack 2 high units The optional stand must have casters All units are intended to slide under a kitchen hood...

Страница 5: ...mber and a drain box The unit is provided with two air and steam vents One is to prevent internal pressure build up This vent pipe exit is located at upper left corner of the unit just above the rear...

Страница 6: ...ge from nails and sharp pieces of wood or staples which might be left in carton walls Writedownthemodelnumber serialnumberandinstallationdateandkeepthisinformation for future reference Space for these...

Страница 7: ...atment system and a regular cartridge replacement schedule is essential 3 Using a Groen water treatment system will provide longer steam generator boiler life higher steam capacity and reduce maintena...

Страница 8: ...strict the flow of air for combustion and ventilation must be removed Do not obstruct the flue cover or rear vents after installation THE AREA DIRECTLY AROUND THE APPLIANCE MUST BE CLEARED OF ALL COMB...

Страница 9: ...ick soap solution or other suitable leak detector should be used Unit Restraining Requirement A The installation shall be made with a connector that complies with the standard for connectors for movab...

Страница 10: ...o matter how slowly Do not over tighten hose connections COLD WATER PRESSURE 30 60 PSI SEE PAGE 6 FOR WATER TREATMENT REQUIREMENTS This equipment is to be installed to comply with the basic plumbing c...

Страница 11: ...a single unit The units are stacked and assembled at the factory A Water Connection The same water supply connection is used for both units At the water inlet valve a inch female NH connector garden h...

Страница 12: ...dy to cook within 25 minutes or less The ready condition is indicated as follows In oven mode Temperature display red LED will stop flashing In Hi or Lo combination mode Temperature display red LED wi...

Страница 13: ...art timer count Time setting can not be readjusted higher or lower during the timing cycle Beeper sounds when the set time cycle is complete Push Cancel to stop the beeper Fan Speed Convection fan can...

Страница 14: ...F the upper limit is 450 F If the cavity temperature is more than 20 F below the selected temperature the TEMPERATURE display flashes until the temperature is within 20 F of the selected temperature t...

Страница 15: ...the cooking modes If oven is in any cooking mode press that mode button to deselect and go to stand by mode F To select clean mode press the CLEAN button G Follow the instructions on the display NOTE...

Страница 16: ...IN CLEANING AND DELIMING INSTRUCTIONS 6 When the unit is to be disconnected from gas supply and moved for servicing and or cleaning the gas restraining cable hook must be disconnected first see Insta...

Страница 17: ...combo and oven modes it is set by the user When the oven is not ready the word PREHEAT is displayed and the temperature display flashes Once the oven comes up to ready PREHEAT disappears and the tempe...

Страница 18: ...d the CANCEL indicator flashes Push CANCEL to stop the beeper Note that this is all the timer does it is a simple kitchen timer It does not stop any cooking process it simply alerts the operator that...

Страница 19: ...quid level probes with a non abrasive stiff brush Two 2 liquid level probes are located on the rear wall of the unit below the fan see photo C Open the inner glass panel and check the light assembly f...

Страница 20: ...MODE RINSE TIME appears in the display to flush the cleaner off the cavity walls 8 This is followed by a drain period CLEAN MODE DRAIN TIME appears in the display followed by the rinse 9 When this is...

Страница 21: ...and the display message changes to OPEN DOOR TO COOL OVEN 7 When the door is opened the display message changes to COOLING 8 When the oven has cooled sufficiently to allow it to continue the display...

Страница 22: ...22 OM CBE 10G Service Log Model No Purchased From Serial No Location Date Purchased Date Installed Purchase Order No For Service Call Date Maintenance Performed Performed By...

Страница 23: ...OM CBE 10G 23 NOTES...

Страница 24: ...REV D 12 10 1055 Mendell Davis Drive Jackson MS 39272 888 994 7636 601 372 3903 Fax 888 864 7636 unifiedbrands net 2010 Unified Brands All Rights Reserved Unified Brands is a wholly owned subsidiary o...

Отзывы: