background image

OM-CBE-10G

IMPORTANT - READ FIRST - IMPORTANT

WARNING:   THE  UNIT  MUST  BE  INSTALLED  BY  PERSONNEL  QUALIFIED  TO  WORK  WITH  ELECTRICITY  AND 

PLUMBING.  IMPROPER INSTALLATION CAN CAUSE INJURY TO PERSONNEL AND/OR DAMAGE TO THE 

EQUIPMENT.  THE UNIT MUST BE INSTALLED IN ACCORDANCE WITH APPLICABLE CODES.

CAUTION: 

SHIPPING STRAPS ARE UNDER TENSION AND CAN SNAP BACK WHEN CUT.

CAUTION: 

DO NOT INSTALL THE UNIT IN ANY WAY WHICH WILL BLOCK THE REAR VENTS, OR WITHIN 2 INCHES OF 

A HEAT SOURCE SUCH AS A BRAISING PAN, DEEP FRYER, CHAR BROILER OR KETTLE.

CAUTION: 

LEVEL THE UNIT AND PITCH IT SLIGHTLY TO THE REAR, TO AVOID DRAINAGE PROBLEMS.

WARNING:   FOLLOW THE WIRING DIAGRAM EXACTLY WHEN CONNECTING A UNIT TO AVOID DAMAGE OR INJURY. 

WIRING DIAGRAM IS LOCATED ON THE INSIDE OF THE RIGHT PANEL.

CAUTION:  

DO NOT USE PLASTIC DRAIN PIPE. DRAIN MUST BE RATED FOR BOILING WATER.

WARNING:   DO NOT CONNECT THE DRAIN DIRECTLY TO A BUILDING DRAIN.

WARNING:   BLOCKING THE DRAIN IS HAZARDOUS.

IMPORTANT:  IMPROPER DRAIN CONNECTION WILL VOID WARRANTY.

IMPORTANT:  DO NOT ALLOW ANY WATER TRAPS IN THE DRAIN LINE.  A TRAP CAN CAUSE PRESSURE TO BUILD UP 

INSIDE THE CAVITY DURING STEAMING, WHICH WILL MAKE THE DOOR GASKET LEAK.

WARNING:  WHEN YOU OPEN THE DOOR, STAY AWAY FROM STEAM COMING OUT OF THE UNIT.  STEAM CAN 

CAUSE BURNS.

WARNING:   BEFORE CLEANING THE OUTSIDE OF THE UNIT, DISCONNECT THE ELECTRIC POWER SUPPLY.  KEEP 

WATER  AND  CLEANING  SOLUTIONS  OUT  OF  CONTROLS  AND  ELECTRICAL  COMPONENTS.    NEVER 

HOSE OR STEAM CLEAN ANY PART OF THE UNIT.

WARNING:   ALLOW COOKING CHAMBER TO COOL COMPLETELY BEFORE CLEANING.

WARNING:   USE MILD CLEANING AGENTS ONLY.  CAREFULLY READ THE WARNINGS AND FOLLOW THE DIRECTIONS 

ON  THE  LABEL  OF  EACH  CLEANING  AGENT.    USE  SAFETY  GLASSES  AND  RUBBER  GLOVES  AS 

RECOMMENDED BY CLEANING AGENT MANUFACTURER.

WARNING:  DO NOT PUT HANDS OR TOOLS INTO THE COOKING CHAMBER UNTIL THE FAN HAS STOPPED TURNING.

WARNING:  DO NOT OPERATE THE UNIT UNLESS THE REMOVABLE RIGHT SIDE PANEL HAS BEEN RETURNED TO ITS 

PROPER LOCATION.

NOTICE: 

DO NOT USE A CLEANING AGENT THAT CONTAINS ANY SULFAMIC ACID, OR ANY CHLORIDE, INCLUDING 

HYDROCHLORIC ACID.  IF THE CHLORIDE CONTENT OF ANY PRODUCT IS UNCLEAR, CONSULT THE 

MANUFACTURER.  DO NOT USE A CLEANING OR DELIMING AGENT THAT CONTAINS MORE THAN 30% 

PHOSPHORIC ACID.

NOTICE: 

DO NOT USE ANY DEGREASER THAT CONTAINS POTASSIUM HYDROXIDE OR SODIUM HYDROXIDE OR 

THAT IS ALKALINE.

WARNING:   USE OF ANY REPLACEMENT PARTS OTHER THAN THOSE SUPPLIED BY GROEN OR THEIR AUTHORIZED 

DISTRIBUTOR VOIDS ALL WARRANTIES AND CAN RESULT IN BODILY INJURY TO THE OPERATOR AND 

DAMAGE THE EQUIPMENT.SERVICE BY OTHER THAN FACTORY-AUTHORIZED PERSONNEL WILL VOID 

ALL WARRANTIES.

WARNING:  HIGH  VOLTAGE  EXISTS  INSIDE  CONTROL  COMPARTMENTS.    DISCONNECT  FROM  BRANCH  CIRCUIT 

BEFORE SERVICING.  FAILURE TO DO SO CAN RESULT IN INJURY OR DEATH.

Содержание (2) CBE-10G

Страница 1: ...Improper installation adjustment alteration service or maintenance can cause property damage injury or death Read the installation operating and maintenance instructions thoroughly before installing o...

Страница 2: ...EANING THE OUTSIDE OF THE UNIT DISCONNECT THE ELECTRIC POWER SUPPLY KEEP WATER AND CLEANING SOLUTIONS OUT OF CONTROLS AND ELECTRICAL COMPONENTS NEVER HOSE OR STEAM CLEAN ANY PART OF THE UNIT WARNING A...

Страница 3: ...page 14 16 Sequence of Operation page 17 18 Maintenance page 19 Cleaning page 20 21 Service Log page 22 NATIONAL FIRE PROTECTION ASSOCIATION 60 Batterymarch Park Quincy Massachusetts 02269 NFPA 70 Th...

Страница 4: ...d The optional stand must have casters Optional stands are available for single and double stack 2 high units The optional stand must have casters All units are intended to slide under a kitchen hood...

Страница 5: ...mber and a drain box The unit is provided with two air and steam vents One is to prevent internal pressure build up This vent pipe exit is located at upper left corner of the unit just above the rear...

Страница 6: ...ge from nails and sharp pieces of wood or staples which might be left in carton walls Writedownthemodelnumber serialnumberandinstallationdateandkeepthisinformation for future reference Space for these...

Страница 7: ...atment system and a regular cartridge replacement schedule is essential 3 Using a Groen water treatment system will provide longer steam generator boiler life higher steam capacity and reduce maintena...

Страница 8: ...strict the flow of air for combustion and ventilation must be removed Do not obstruct the flue cover or rear vents after installation THE AREA DIRECTLY AROUND THE APPLIANCE MUST BE CLEARED OF ALL COMB...

Страница 9: ...ick soap solution or other suitable leak detector should be used Unit Restraining Requirement A The installation shall be made with a connector that complies with the standard for connectors for movab...

Страница 10: ...o matter how slowly Do not over tighten hose connections COLD WATER PRESSURE 30 60 PSI SEE PAGE 6 FOR WATER TREATMENT REQUIREMENTS This equipment is to be installed to comply with the basic plumbing c...

Страница 11: ...a single unit The units are stacked and assembled at the factory A Water Connection The same water supply connection is used for both units At the water inlet valve a inch female NH connector garden h...

Страница 12: ...dy to cook within 25 minutes or less The ready condition is indicated as follows In oven mode Temperature display red LED will stop flashing In Hi or Lo combination mode Temperature display red LED wi...

Страница 13: ...art timer count Time setting can not be readjusted higher or lower during the timing cycle Beeper sounds when the set time cycle is complete Push Cancel to stop the beeper Fan Speed Convection fan can...

Страница 14: ...F the upper limit is 450 F If the cavity temperature is more than 20 F below the selected temperature the TEMPERATURE display flashes until the temperature is within 20 F of the selected temperature t...

Страница 15: ...the cooking modes If oven is in any cooking mode press that mode button to deselect and go to stand by mode F To select clean mode press the CLEAN button G Follow the instructions on the display NOTE...

Страница 16: ...IN CLEANING AND DELIMING INSTRUCTIONS 6 When the unit is to be disconnected from gas supply and moved for servicing and or cleaning the gas restraining cable hook must be disconnected first see Insta...

Страница 17: ...combo and oven modes it is set by the user When the oven is not ready the word PREHEAT is displayed and the temperature display flashes Once the oven comes up to ready PREHEAT disappears and the tempe...

Страница 18: ...d the CANCEL indicator flashes Push CANCEL to stop the beeper Note that this is all the timer does it is a simple kitchen timer It does not stop any cooking process it simply alerts the operator that...

Страница 19: ...quid level probes with a non abrasive stiff brush Two 2 liquid level probes are located on the rear wall of the unit below the fan see photo C Open the inner glass panel and check the light assembly f...

Страница 20: ...MODE RINSE TIME appears in the display to flush the cleaner off the cavity walls 8 This is followed by a drain period CLEAN MODE DRAIN TIME appears in the display followed by the rinse 9 When this is...

Страница 21: ...and the display message changes to OPEN DOOR TO COOL OVEN 7 When the door is opened the display message changes to COOLING 8 When the oven has cooled sufficiently to allow it to continue the display...

Страница 22: ...22 OM CBE 10G Service Log Model No Purchased From Serial No Location Date Purchased Date Installed Purchase Order No For Service Call Date Maintenance Performed Performed By...

Страница 23: ...OM CBE 10G 23 NOTES...

Страница 24: ...REV D 12 10 1055 Mendell Davis Drive Jackson MS 39272 888 994 7636 601 372 3903 Fax 888 864 7636 unifiedbrands net 2010 Unified Brands All Rights Reserved Unified Brands is a wholly owned subsidiary o...

Отзывы: