Page 57
OCF 6.1 Open Channel Flow Monitor
Optional Sensor PZ32T
Maximum Range:
32 ft. (10 m)
Deadband (blanking):
Programmable, minimum 12” (305
mm)
Beam Angle:
8° at 3 DB
Temperature Compensation:
Automatic, continuous
Operating Frequency:
42 KHz
Exposed Materials:
PVC and Teflon
Operating Temperature:
- 40° to 150°F (-40° to 65°C)
Operating Pressure:
20 psi (1.35 Bar) maximum
Mounting:
¾” NPT (PVC isolation coupling
supplied)
Sensor Cable:
RG62AU coaxial, 25 ft. (7.6 m)
standard
Hazardous Rating:
with optional Intrinsic Safety Barrier:
CSA, Class I,II,III, Div. I,II, Groups
C,D,E,F,G
Note: Max Range reduced to 25 ft
(7.6 m) with ISB option.
Standard PZ34
Maximum Range:
32 ft. (10 m)
Minimum Range (Deadband):
16" (406.4 mm)
Operating Frequency:
46 KHz
Beam Angle:
8º
Temperature Compensation:
Automatic, continuous
Operating Temperature:
-40° to 150ºF (-40° to 65ºC)
Maximum Operating Pressure:
20 psi (1.35 Bar)
Exposed Materials:
PVC
Sensor Mounting:
¾” NPT
Maximum Cable Length:
500 ft (152 m)
Optional Hazardous Rating:
CSA rated Intrinsically Safe
Class I, Groups C,D, Class II,
Groups E,F,G with optional
Intrinsic Safety Barrier.
Note: Max Range reduced to
25 ft (7.8 m) with ISB option.