Page 19
OCF 6.1 Open Channel Flow Monitor
RELAY PARAMETERS
Relay
Press
and
or
to select a relay (2 relays are
standard, 4 additional are optional).
Function
Press
or
to select
Off
,
Temperature
,
Pulse
or
Flow
.
Temperature
Air temperature at the sensor location.
Press
and
and set the relay On
and Off for specific temperatures.
Pulse
Press
and set digits to the flow
volume increment required between
relay pulses. Use this feature for
remote samplers, chlorinators or
totalizers. Minimum time between
pulses is 2.25 seconds and pulse
duration is 350 milliseconds.
Flow
Press
to
Mode
and
to select
Pump
,
Low Alarm
or
Hi Alarm
.
Note:
Function
setting
Flow
will change according to selections made
under
Units /Mode
eg
Level
,
Range
,
Volume
or
HRT
.
Press
to return to
Menu Selections
.
LOE mode
Set relay state for ‘echo loss’ event (
On
,
Off
or
Hold
)
- - Re l a y Pa r a me t e r s - -
Re l a y
1
F l o w
Fu n c t i o n
1 0 0 0 0 USG/ m
On
8 0 0 0 USG/ m
Of f
L OE mo d e
Of f