Page 49
OCF 6.1 Open Channel Flow Monitor
Register
Address
Description
Register
Type
Format Type
Comments
30325
Previous day Volume
Total - USMG
Input Register
Floating Point Register (1 of 2) USMG = US Million
Gallons
30326
Previous day Volume
Total - USMG
Input Register
Floating Point Register (2 of 2) USMG = US Million
Gallons
30327
Previous day Volume
Total - IG
Input Register
Floating Point Register (1 of 2) IG = Imperial Gallons
30328
Previous day Volume
Total - IG
Input Register
Floating Point Register (2 of 2) IG = Imperial Gallons
30329
Previous day Volume
Total - IMG
Input Register
Floating Point Register (1 of 2) IMG = Imperial Million
Gallons
30330
Previous day Volume
Total - IMG
Input Register
Floating Point Register (2 of 2) IMG = Imperial Million
Gallons
30331
Previous day Volume
Total - bbl
Input Register
Floating Point Register (1 of 2) bbl = US Oil Barrel = 42
Gallons
30332
Previous day Volume
Total - bbl
Input Register
Floating Point Register (2 of 2) bbl = US Oil Barrel = 42
Gallons
30501
Sensor Range - inches
Input Register
Floating Point Register (1 of 2) Only used when through-
air sensor is installed.
30502
Sensor Range - inches
Input Register
Floating Point Register (2 of 2) Only used when through-
air sensor is installed.
30503
Sensor Range - feet
Input Register
Floating Point Register (1 of 2) Only used when through-
air sensor is installed.
30504
Sensor Range - feet
Input Register
Floating Point Register (2 of 2) Only used when through-
air sensor is installed.
30505
Sensor Range - mm
Input Register
Floating Point Register (1 of 2) Only used when through-
air sensor is installed.
30506
Sensor Range - mm
Input Register
Floating Point Register (2 of 2) Only used when through-
air sensor is installed.
30507
Sensor Range - meters Input Register
Floating Point Register (1 of 2) Only used when through-
air sensor is installed.
30508
Sensor Range - meters Input Register
Floating Point Register (2 of 2) Only used when through-
air sensor is installed.
30525
Sensor Level - inches
Input Register
Floating Point Register (1 of 2)
30526
Sensor Level - inches
Input Register
Floating Point Register (2 of 2)
30527
Sensor Level - feet
Input Register
Floating Point Register (1 of 2)
30528
Sensor Level - feet
Input Register
Floating Point Register (2 of 2)
30529
Sensor Level - mm
Input Register
Floating Point Register (1 of 2)
30530
Sensor Level - mm
Input Register
Floating Point Register (2 of 2)
30531
Sensor Level - meters
Input Register
Floating Point Register (1 of 2)
30532
Sensor Level - meters
Input Register
Floating Point Register (2 of 2)