
Page 17
AVFM 6.1 Area-Velocity Flow Meter
CUSTOM CHANNELS
Reset Data
Old data MUST be removed before entering data for a new
channel. Press
then press
to
Yes
and press
to clear
old data.
Max Height
Enter the maximum height of the channel.
Division
Divide the maximum height into equal increments (maximum
of 40) and enter this division value (example 1”, 1 cm etc.)
Increment #
Enter the increment number if you want to edit a previous
entry or to skip entering widths for some levels (Note: The
custom channel will interpolate widths between entry points).
Width
Enter the measured width of the channel at the level shown
(Note: To enter 0 width you must press
and then
to store
a 0 width data point).
Level
Displays the level of the channel for each increment and width
entry.
Note:
Custom channel data in equal width increments with variable height
measurements must be converted to the format shown above using the “Channel
Data Translator” PC software.
Содержание AVFM 6.1
Страница 2: ...Note This page has been left blank intentionally ...
Страница 28: ...Page 28 AVFM 6 1 Area Velocity Flow Meter ...
Страница 34: ...Page 34 AVFM 6 1 Area Velocity Flow Meter Resistance vs Temperature ...
Страница 40: ...Page 40 AVFM 6 1 Area Velocity Flow Meter SS PIPE MOUNTING BAND OPTION VSJ ...
Страница 61: ...Page 61 AVFM 6 1 Area Velocity Flow Meter Dual Non Contacting Sensor Configuration ...