22
Rotary Mulcher RM 232
Hydraulics
Hydraulic hoses
With/without installed flow divider, 3 hoses must alway be installed as follows:
DRAIN
•
The smallest hose is for DRAIN,
marked in BLUE
.
•
The hose is connected to a pressureless
(0 bar)
tank
.
•
It must
NOT
be connected with RETURN
The drain pressure must
never
exceed 2,0 bar.
If this is not complied with, the hydraulic motor will be damaged, and the warranty will no
longer apply.
PRESSURE
•
The middle hose is for PRESSURE,
marked in RED
.
•
The hose is connected to Pressure (P) with max. 200 bar pressure
RETURN
•
The biggest hose is for RETURN,
marked in GREEN.
•
The hose is connected RETURN, on the double action outlet.
•
Min pressure 5 bar (if the pressure is lower, then mount a checkvalve
with an opening pressure at 4 bar (checkvalve partno. CA19/4))
•
Max. counter-pressure 15 bars at the motor.
On all machines supplied by GreenTec, all connecting hoses are color and text labeled
with labels as illustrated above.
Flow divider (on multi carrier)
It is very important that the rotary mulcher is connected to the correct flow, 50 l/min gives
the correct rotation speed for the blades. When it goes beyond 50 l/min the machine will
"over-speed" with the risk of extreme wear, cracking and eventually the separation of the
machine.
Содержание RM 232
Страница 1: ...3 Edition 2019 ...
Страница 44: ......