Page 12
(while device is
powered ON)
LIDAR data collection will begin and
end automatically based on the user
defined velocity and flight-height or -
speed parameter values.
0-2 s (repress)
DA Indicator LED
Off
Not recording IMU, GNSS, or Laser
Scan data
Detailed Figures and Tables describing LiAir 220N Ultralight Indicator LED panel:
Figure 3. Partial View of LiAir 220N Ultralight Control Panel
Table 4. Detailed explanations of Indicator LED light statuses displayed on the LiAir 220N
Ultralight Control Panel
Explanation of Indicator LEDs
LED
Light Status
Description Status
ON/OFF
Flashing
Red
(flashes two times per
second)
System is in initializing
Flicking slowly
Red
(flashes one
time per second)
System initialization (completed)
Solid
Red
System started successfully
RECORD
Solid
Blue
Project created and IMU+GNSS data are
being collected
Flicking slowly
Blue
(flashes one
time per second)
Storage is smaller than 6 GB
IMU
Solid
Blue
IMU’s initial alignment (completed)
Solid
Red
IMU is not aligned