Pellet burner GP 45 IV 48
Burner operation
with heating output
over the nominal
Change the burner’s heating output by
changing its heating output level;
19.
Alarm code, shown
on
the
burner’s
controller display
Problem
in
the
burner operation
Check the code meaning in the next table.
Ask for assistance from servicing technician;
20.
The burner has
stopped,
but
it
operates
after
restarting
The photo-sensor
submits
wrong
information to the
control module
Check the fuel quantity over the fire-grate.
Ask for assistance from servicing specialist;
21.
High
flue
gas
temperature (if a
thermometer
is
installed)
Dirty
heat
exchanging
surfaces
depending on the
appliance type and
the operation mode
It is necessary to clean the appliance heat
exchanging surfaces;
22.
Presence of smoke
in the boiler room
after
period
of
operation
Dirty or clogged
tract for extraction
of the flue gasses
out
of
the
appliance – heat
exchanger
Cleaning of the appliance – heat exchanger,
from the ash residues;
23.
The burner stops
when it reaches
the
assigned
temperature
or
when it performs
periodical
intermediate stops
for blowing, but
shows
message:
“Eror
-
final
combustion failed”
Pellets with high
ash content, fuel
deposits in the pipe
It is necessary to reduce the burner’s heating
output and to replace with fuel corresponding
to the requirements for reliable operation of
the burner;
24.
Other,
not
presented failures
Ask for servicing assistance;
EXPLANATION:
*: excessive heating of the pellets inlet pipe, in most cases resulting from contamination of
the appliance’s heat exchanging surfaces, to which the pellet burner is mounted;
** In case of insufficient chimney draught it is recommended to ask for servicing assistance –
cleaning, chimney inspection or others.