![Gree R410A Скачать руководство пользователя страница 60](http://html.mh-extra.com/html/gree/r410a/r410a_service-manual_2260090060.webp)
Super Free Match
Service Manual
CONTROL
56
When the unit operates under X-FAN mode, press "X-FAN" button can turn off X-FAN function.
Indoor fan stops operation immediately.
9)
TEMP
Press this button can see indoor set temperature, indoor ambient temperature or outdoor ambient temperature
on indoor unit’s display. Temperature is set circularly by remote controller as below:
When selecting "
" by remote controller or no display, temperature indicator on indoor unit displays
set temperature.
When selecting "
" by remote controller, temperature indicator on indoor unit displays indoor
ambient temperature.
When selecting "
" by remote controller, temperature indicator on indoor unit displays outdoor
ambient temperature.
Note:
Outdoor ambient temperature display may can’t be selected for some models. When indoor unit receives
"
" signal, it displays indoor set temperature.
Only for the model whose indoor unit has dual-8 display.
10)
TIMER
At ON status, press this button once can set TIMER OFF. The character of HOUR and OFF will flash.
Press "
+
" or "
-
" button within 5s can adjust the time of TIMER ON. After each pressing of "
+
" or "
-
" button, time will increase or decrease half an hour. When holding "
+
" or "
-
" button, 2s later,
the time will change quickly until to reach to your required time. After that, press "TIMER" button to
confirm it. The character of HOUR and OFF won’t flash again. Cancel TIMER OFF: Press "TIMER"
button again under TIMER OFF status.
At OFF status, press this button once can set TIMER ON. Please refer to TIMER off for detailed
operation.
Cancel TIMER ON: Press "TIMER" button again under TIMER ON status.
Note:
Time setting range: 0.5-24 hours.
Time interval between two operations can’t exceed 5s. Otherwise, remote controller will exit the setting
status automatically.
11)
TURBO
When pressing this button under cooling or heating mode, air conditioner will enter into quick cooling or
quick heating mode. The character of "TURBO" is displayed on remote controller. Press this button again to exit
turbo function and the character of "TURBO" will be disappeared on remote controller.
12)
SLEEP
Press this button under cooling, heating mode can start up sleep function. "
" icon will be displayed on
remote controller. Press this button again to cancel sleep function. "
"icon on remote controller will be
Содержание R410A
Страница 1: ...SUPER FREE MATCH SERIES SERVICE MANUAL T1 R410A 50Hz GC201306 CENTRAL AIR CONDITIONERS ...
Страница 5: ...Super Free Match Service Manual PRODUCT 1 PRODUCT ...
Страница 28: ...Super Free Match Service Manual CONTROL 24 CONTROL ...
Страница 29: ...Super Free Match Service Manual CONTROL 25 Control 1 OPERATION FLOWCHART ...
Страница 31: ...Super Free Match Service Manual CONTROL 27 1 2 Heating Operation ...
Страница 66: ...Super Free Match Service Manual INSTALLATION 62 INSTALLATION ...
Страница 97: ...Super Free Match Service Manual INSTALLATION 93 ...
Страница 118: ...Super Free Match Service Manual INSTALLATION 114 7 Electrical Wiring Work 7 1 Wiring Connection Precept 1 Precept 2 ...
Страница 129: ...Super Free Match Service Manual MAINTENANCE N 125 MAINTENANCE ...
Страница 152: ...Super Free Match Service Manual MAINTENANCE 148 5 Console GEH 09 AA K3DNA1C I GEH 12 AA K3DNA1C I GEH 18 AA K3DNA1C I ...
Страница 153: ...Super Free Match Service Manual MAINTENANCE N 149 4 2 3 BU module FXB3A K ...
Страница 154: ...Super Free Match Service Manual MAINTENANCE 150 FXB5A K ...
Страница 203: ...Super Free Match Service Manual MAINTENANCE N 199 7 2 3 Cassette type GKH 12 BA K3DNA2A I GKH 18 BA K3DNA2A I ...