Super Free Match
Service Manual
INSTALLATION
105
The sorts
The pipes
Length
(
m
)
Between outdoor unit and BU
L1+L2+L3+L4+L5
≤
55
GWHD(48S)NM3CO
≤
80
Total length between
indoor units and BU
GWHD(56S)NM3CO
1A+1B+1C+2A+2B+2C+
3A+3B+3C
≤
90
Between indoor unit and BU module
1A;1B;1C;2A;2B;2C;3A;3B;3C
≤
15
Maximum
allowable
length
Between indoor unit and the 1st branch
L4+1B;L2+L5+2A;
L2+L3+3B
≤
40
Between outdoor and indoor units
H1
≤
30
Between outdoor units and BU
H2
≤
30
Between BU and BU modules
H3
≤
15
Maximum
allowable
length
Between indoor and indoor units
H4
≤
15
Between outdoor and the 1st branch
L1
≥
5
Minimum
allowable
length
Between BU and the branch
L3;L4;L5
as possible
as short
6.3
Dimension of Connecting Pipe
Sorts Gas
Pipe
(
mm
)
Liquid
Pipe
(
mm
)
GWHD(48S)NM3CO
Φ
15.9
Outdoor unit
GWHD(56S)NM3CO
Φ
19.05
Φ
9.52
Between outdoor unit and the 1st branch
The pipe L1
Φ
19.05
Φ
9.52
Between the 1st and the 2nd branch
The pipe L2
Φ
15.9
Φ
9.52
6.4
Connection of Branch Pipe
1)
If two or three BU modules used, Y-type branch pipe of FQ01A/A will be chosen.
FQ01A/A (Liquid pipe) FQ01A/A (Gas pipe)
2)
Y-type branch pipe is equipped with auxiliary tubes to adjust the diameter of different pipes. If the
dimension of the pipe selected is different from the dimension of branch pipe joint, Cut
the
copper tube
in the middle with tube cutter and clear up burrs.
Plea
se do that as following figure.
3)
Y-type branch pipe must be installed in vertical or horizontal direction. In the inlet of the branch pipe,
keep at least 500mm straight pipe.
Содержание R410A
Страница 1: ...SUPER FREE MATCH SERIES SERVICE MANUAL T1 R410A 50Hz GC201306 CENTRAL AIR CONDITIONERS ...
Страница 5: ...Super Free Match Service Manual PRODUCT 1 PRODUCT ...
Страница 28: ...Super Free Match Service Manual CONTROL 24 CONTROL ...
Страница 29: ...Super Free Match Service Manual CONTROL 25 Control 1 OPERATION FLOWCHART ...
Страница 31: ...Super Free Match Service Manual CONTROL 27 1 2 Heating Operation ...
Страница 66: ...Super Free Match Service Manual INSTALLATION 62 INSTALLATION ...
Страница 97: ...Super Free Match Service Manual INSTALLATION 93 ...
Страница 118: ...Super Free Match Service Manual INSTALLATION 114 7 Electrical Wiring Work 7 1 Wiring Connection Precept 1 Precept 2 ...
Страница 129: ...Super Free Match Service Manual MAINTENANCE N 125 MAINTENANCE ...
Страница 152: ...Super Free Match Service Manual MAINTENANCE 148 5 Console GEH 09 AA K3DNA1C I GEH 12 AA K3DNA1C I GEH 18 AA K3DNA1C I ...
Страница 153: ...Super Free Match Service Manual MAINTENANCE N 149 4 2 3 BU module FXB3A K ...
Страница 154: ...Super Free Match Service Manual MAINTENANCE 150 FXB5A K ...
Страница 203: ...Super Free Match Service Manual MAINTENANCE N 199 7 2 3 Cassette type GKH 12 BA K3DNA2A I GKH 18 BA K3DNA2A I ...
Страница 217: ...JF00301896 ...