Super Free Match
Service Manual
CONTROL
42
5) Press
to select the swing angle.
3.2.3 Guide for Optional Operation
1)
About X-FAN
This function indicates that moisture in the evaporator of the indoor unit will be dried after the unit is stopped
to avoid mould.
◆
X-FAN ON: When press the ON/OFF button to turn off the unit, the indoor fan will continue running
for about another 10 minutes at the low speed. In this case, the indoor fan can be stopped directly by
pressing the button X-FAN.
◆
X-FAN OFF: When press the ON/OFF button to turn off the unit, the whole unit will be stopped
completely.
2)
About AFTERHEAT X-FAN
Under the Heat mode or Auto Heat mode, if the unit is turned off, the compressor and outdoor fan will stop
running immediately and the upper and lower guide board will rotate to the horizontal position, while the indoor
fan will still run at the low fan speed. Then, 10 seconds later, the unit will stop completely.
3)
About AUTO RUN
When AUTO RUN is selected, the setting temperature will not be displayed on the LCD and the unit will
choose the suitable running mode automatically in accordance with the room temperature.
◆
About TURBO
If this function is activated, the unit will run at super-high fan speed to cool or heat quickly so that the
ambient temperature will approaches the preset temperature as soon as possible.
Содержание R410A
Страница 1: ...SUPER FREE MATCH SERIES SERVICE MANUAL T1 R410A 50Hz GC201306 CENTRAL AIR CONDITIONERS ...
Страница 5: ...Super Free Match Service Manual PRODUCT 1 PRODUCT ...
Страница 28: ...Super Free Match Service Manual CONTROL 24 CONTROL ...
Страница 29: ...Super Free Match Service Manual CONTROL 25 Control 1 OPERATION FLOWCHART ...
Страница 31: ...Super Free Match Service Manual CONTROL 27 1 2 Heating Operation ...
Страница 66: ...Super Free Match Service Manual INSTALLATION 62 INSTALLATION ...
Страница 97: ...Super Free Match Service Manual INSTALLATION 93 ...
Страница 118: ...Super Free Match Service Manual INSTALLATION 114 7 Electrical Wiring Work 7 1 Wiring Connection Precept 1 Precept 2 ...
Страница 129: ...Super Free Match Service Manual MAINTENANCE N 125 MAINTENANCE ...
Страница 152: ...Super Free Match Service Manual MAINTENANCE 148 5 Console GEH 09 AA K3DNA1C I GEH 12 AA K3DNA1C I GEH 18 AA K3DNA1C I ...
Страница 153: ...Super Free Match Service Manual MAINTENANCE N 149 4 2 3 BU module FXB3A K ...
Страница 154: ...Super Free Match Service Manual MAINTENANCE 150 FXB5A K ...
Страница 203: ...Super Free Match Service Manual MAINTENANCE N 199 7 2 3 Cassette type GKH 12 BA K3DNA2A I GKH 18 BA K3DNA2A I ...
Страница 217: ...JF00301896 ...