Super Free Match
Service Manual
PRODUCT
10
¾
Cozy
Model
GWH(07)MA-K
3DNA3E/I
GWH(09)MA-K
3DNA3E/I
GWH(12)MB-K
3DNA3E/I
GWH(18)MC-K
3DNA3E/I
Cooling kW
2.1 2.6 3.5 5.3
Capacity
Heating kW
2.6 2.8 3.8 5.8
Power
supply
V-Ph-Hz 220~240-1-50 220~240-1-50 220~240-1-50 220~240-1-50
Motor power input
kW
0.03
0.03
0.04
0.045
m
3
/h
450 500 630 850
Air flow volume
CFM
265 294 371 500
Sound pressure level
(SH/H/M/L)
dB(A)
36/34/31/28/- 37/34/31/28/- 38/34/32/30/- 46/43/40/36/-
Output
kW
0.01 0.01 0.02 0.02
Fan motor
Running
current
A
0.14 0.14 0.22 0.31
Gas inch
3/8
″
(
Φ
9.52mm)
3/8
″
(
Φ
9.52mm)
3/8
″
(
Φ
9.52mm) 1/2
″
(
Φ
12.7mm)
Liquid inch
1/4
″
(
Φ
6.35mm)
1/4
″
(
Φ
6.35mm)
1/4
″
(
Φ
6.35mm) 1/4
″
(
Φ
6.35mm)
Connecting
pipe
Connection method
Flare Connection Flare Connection Flare Connection Flare
Connection
External
dia.
mm
Φ
20
Φ
20
Φ
20
Φ
20
Drain pipe
Thickness
mm
1.5 1.5 1.5 1.5
Outline
dimension
W×D×H mm
790×170×265 790×170×265 845×180×275 940×200×298
Package
dimension
W×D×H mm
873×251×370 873×251×370 918×258×370 1013×288×395
Net Weight/ Gross weight
kg
9/11 9/11
10/12.5
13/16
20'GP
348 348 336 254
40' GP
732 732 684 541
Loading quantity
40' HQ
852 852 798 609
Notes:
a. The rated cooling capacity data is measured under the following work condition: Indoor Temperature is 27
℃
DB, 19
℃
WB. Outdoor Temperature is 35
℃
DB. The rated heating capacity data is measured under the following
work condition: Indoor Temperature is 20
℃
DB. Outdoor Temperature is 7
℃
DB, 6
℃
WB.
b. The data will change with the change of products. Refer to those parameters listed on nameplate.
c. Noise was tested in semi-silenced room, so the actual noise value will be a little higher for change of ambient.
Содержание R410A
Страница 1: ...SUPER FREE MATCH SERIES SERVICE MANUAL T1 R410A 50Hz GC201306 CENTRAL AIR CONDITIONERS ...
Страница 5: ...Super Free Match Service Manual PRODUCT 1 PRODUCT ...
Страница 28: ...Super Free Match Service Manual CONTROL 24 CONTROL ...
Страница 29: ...Super Free Match Service Manual CONTROL 25 Control 1 OPERATION FLOWCHART ...
Страница 31: ...Super Free Match Service Manual CONTROL 27 1 2 Heating Operation ...
Страница 66: ...Super Free Match Service Manual INSTALLATION 62 INSTALLATION ...
Страница 97: ...Super Free Match Service Manual INSTALLATION 93 ...
Страница 118: ...Super Free Match Service Manual INSTALLATION 114 7 Electrical Wiring Work 7 1 Wiring Connection Precept 1 Precept 2 ...
Страница 129: ...Super Free Match Service Manual MAINTENANCE N 125 MAINTENANCE ...
Страница 152: ...Super Free Match Service Manual MAINTENANCE 148 5 Console GEH 09 AA K3DNA1C I GEH 12 AA K3DNA1C I GEH 18 AA K3DNA1C I ...
Страница 153: ...Super Free Match Service Manual MAINTENANCE N 149 4 2 3 BU module FXB3A K ...
Страница 154: ...Super Free Match Service Manual MAINTENANCE 150 FXB5A K ...
Страница 203: ...Super Free Match Service Manual MAINTENANCE N 199 7 2 3 Cassette type GKH 12 BA K3DNA2A I GKH 18 BA K3DNA2A I ...