Super Free Match
Service Manual
CONTROL
49
10)
—:
Presetting temperature can be decreased. Press this button, the temperature can be button set up, continuously
press this button and hold for two seconds, the relative contents can quickly change, until unhold this button and
send the order that the
℃
(
℉
) signal will be displayed all the time. The temperature adjustment is unavailable
under the Auto mode, but the order can be sent by if pressing this button.
11)
QUIET:
Press this button, the Quiet status is under the Auto Quiet mode (display "
"signal ) and Quiet mode
(display "
" signal) and Quiet OFF (there is no signal of "
"displayed),after powered on, the Quiet OFF is
defaulted. Note: the Quiet function cannot be set up in Fan and Dry mode; Under the Quiet mode (Display "
"
Under the Quiet mode (Display "
" signal), the fan speed is not available.
12)
SWING UP and DOWN
Press this button
to set up &down swing angle, which circularly changes as below:
This remote controller is universal. If it receives threes kinds of following status, the swing angle will remain
original.
If guide louver is stopped when it is swinging up and down, it will remain its present position.
indicates guide louver swings back and forth in the five places, as shown in the figure.
13)
SWING LEFT and RIGHT
Press this button
to set left & right swing angle cycling as below:
14)
TIMER OFF
One press this key to enter into TIMER OFF setup, in which case the TIMER OFF icon will blink. The
method of setting is the same as for TIMER ON.
15)
TIMER ON
Timer On setting : Signal “ON” will blink and display, signal will
conceal, the numerical section will
become the timer on setting status. During 5 seconds blink, by pressing
+
or
-
button to adjust the time value
of numerical section, every press of that button, the value will be increased or decreased 1 minute. Hold pressing
+
or
-
button, 2 seconds later , it quickly change, the way of change is: During the initial 2.5 seconds, ten
numbers change in the one place of minute, then the one place is constant, ten numbers change in the tens place of
minute at 2.5 seconds speed and carry. During 5s blink, press the Timer button, the timer setting succeeds. The
Timer On has been set up; repress the timer button, the Timer On will be canceled. Before setting the Timer,
please adjust the Clock to the current actual time.
16)
I FEEL:
Содержание R410A
Страница 1: ...SUPER FREE MATCH SERIES SERVICE MANUAL T1 R410A 50Hz GC201306 CENTRAL AIR CONDITIONERS ...
Страница 5: ...Super Free Match Service Manual PRODUCT 1 PRODUCT ...
Страница 28: ...Super Free Match Service Manual CONTROL 24 CONTROL ...
Страница 29: ...Super Free Match Service Manual CONTROL 25 Control 1 OPERATION FLOWCHART ...
Страница 31: ...Super Free Match Service Manual CONTROL 27 1 2 Heating Operation ...
Страница 66: ...Super Free Match Service Manual INSTALLATION 62 INSTALLATION ...
Страница 97: ...Super Free Match Service Manual INSTALLATION 93 ...
Страница 118: ...Super Free Match Service Manual INSTALLATION 114 7 Electrical Wiring Work 7 1 Wiring Connection Precept 1 Precept 2 ...
Страница 129: ...Super Free Match Service Manual MAINTENANCE N 125 MAINTENANCE ...
Страница 152: ...Super Free Match Service Manual MAINTENANCE 148 5 Console GEH 09 AA K3DNA1C I GEH 12 AA K3DNA1C I GEH 18 AA K3DNA1C I ...
Страница 153: ...Super Free Match Service Manual MAINTENANCE N 149 4 2 3 BU module FXB3A K ...
Страница 154: ...Super Free Match Service Manual MAINTENANCE 150 FXB5A K ...
Страница 203: ...Super Free Match Service Manual MAINTENANCE N 199 7 2 3 Cassette type GKH 12 BA K3DNA2A I GKH 18 BA K3DNA2A I ...
Страница 217: ...JF00301896 ...