![Gravely 991001-008 Скачать руководство пользователя страница 65](http://html1.mh-extra.com/html/gravely/991001-008/991001-008_service-manual_2258607065.webp)
13 - 65
Promaster 100 - Briggs & Stratton
Normally open switches, manually activated.
Contact resistance is 0.1-0.3 ohms when correct.
Pins 85-86 coil. Resistance is 87-100 ohms.
Contact resistance is 0.1-0.3 ohms when correct.
Pins 30-87A normally closed.
Normally open contacts. Large terminal contact resistance is 3 to 5 ohms.
Small terminal contact resistance is 0.1 to 0.3 ohms.
Left Interlock Switch
Off
Run
Start
Brown
12.00 Vdc
12.00 Vdc
Brown/White
12.00 Vdc
12.00 to ground
Relay
Off
Run
Start
Red and Green (86)
12.00 Vdc
12.00 Vdc
Black (87A)
Connected to ground kill thru relay pin 30
Green (85)
12.00 Vdc
12.00 to ground
Green (30)
Connected to ground
Time Delay Module
Off
Run
Start
Brown
12.00 Vdc
12.00 Vdc
Yellow
12.00 Vdc
12.00 Vdc
Green
12.00 Vdc
12.00 Vdc
Solenoid
Off
Run
Start
Red (battery input)
12.00 Vdc
12.00 Vdc
Red (starter lead)
Connected to ground kill thru relay pin 30
Brown (from key switch)
12.00 Vdc
12.00 to ground
Brown (to module and switches
Connected to ground circuit
Содержание 991001-008
Страница 38: ...12 38 Figure 23 LP Low Pressure HP High Pressure FFBW Fluid Both Ways ...
Страница 40: ...12 40 Models 992013 014 015 016 PF2020 Figure 25 ...
Страница 54: ...13 54 Promaster 100 Kohler Command 50 Deck with Lift Models 991006 ...
Страница 59: ...13 59 Promaster 100 Kohler 16 18 HP ...
Страница 63: ...13 63 Promaster 100 Briggs Stratton ...
Страница 68: ...13 68 Model 992010 011 Briggs Stratton ...
Страница 75: ...13 75 Model 992015 016 Kohler 20 HP ...
Страница 76: ...13 76 Model 992301 Kohler 20 and 25 HP ...