![Gravely 991001-008 Скачать руководство пользователя страница 55](http://html1.mh-extra.com/html/gravely/991001-008/991001-008_service-manual_2258607055.webp)
13 - 55
Promaster 100 Kohler Command - 50" Deck with Lift, Models 991005, 006
Contact resistance is 0.1-0.3 ohms when correct.
Pins 85-86 coil resistance is 87-100 ohms.
Pins 30-87A normally closed.
Contact resistance is 0.1-0.3 ohms when correct.
Pins 85-86 coil resistance is 87-100 ohms.
Pins 30-87A normally closed.
Contact resistance is 0.1-0.3 ohms when correct.
Ignition Switch
Off
Run
Start
Red (B)
12.00 Vdc
12.00 Vdc
12.00 Vdc
Purple (A)
12.00 Vdc
12.00 Vdc
Red/Violet (S2)
12.00 Vdc
12.00 Vdc
Brown (S1)
12.00 Vdc
12.00 Vdc
Relay - Seat
Off
Run
Start
Pink (85)
12.00 Vdc
12.00 Vdc
Purple (86)
12.00 Vdc
12.00 Vdc
Yellow/Red (87)
12.00 Vdc
12.00 Vdc
Purple (30)
12.00 Vdc
12.00 Vdc
Open (87A)
Relay - Start/Kill
Off
Run
Start
Black (85)
To Ground
Yellow/Red (86)
12.00 Vdc
12.00 Vdc
Open (87)
Black (30)
To Ground
White/Black (87A)
From Engine Magneto
Содержание 991001-008
Страница 38: ...12 38 Figure 23 LP Low Pressure HP High Pressure FFBW Fluid Both Ways ...
Страница 40: ...12 40 Models 992013 014 015 016 PF2020 Figure 25 ...
Страница 54: ...13 54 Promaster 100 Kohler Command 50 Deck with Lift Models 991006 ...
Страница 59: ...13 59 Promaster 100 Kohler 16 18 HP ...
Страница 63: ...13 63 Promaster 100 Briggs Stratton ...
Страница 68: ...13 68 Model 992010 011 Briggs Stratton ...
Страница 75: ...13 75 Model 992015 016 Kohler 20 HP ...
Страница 76: ...13 76 Model 992301 Kohler 20 and 25 HP ...