![Gravely 991001-008 Скачать руководство пользователя страница 62](http://html1.mh-extra.com/html/gravely/991001-008/991001-008_service-manual_2258607062.webp)
13 - 62
Promaster 100 Briggs/Stratton -16 HP
Installation checkout: Make sure that all switches are in
their proper position: PTO switch off, Neutral switches
activated. (T-levers centered).
Step 1:
Check out the battery. Use a hydrometer on all the
battery cells to see if one or more is bad. Also use a
voltmeter to check for proper voltage. Replace the
battery if necessary and/or charge to proper level.
Step 2:
Use a voltmeter to make sure you have power to
terminal B in the off position on the back of the key
switch. If you don’t have power to terminal B, check the
25-amp fuse or connection at the start solenoid.
Step 3:
With the key switch in the RUN position see that power
has been transferred to terminals L, and A. Terminal A
supplies power to the relay (pin 86) and on to the seat
switch to activate the holding circuit for the time delay,
and fuel shut off solenoid. Terminal A supplies power to
the hourmeter and oil PSI light, and brings in charge
power from the engine to the battery.
Terminal M grounds the key switch with the unit.
Terminal G provides an additional ground for the kill
circuit of the engine.
Step 4:
With the key in the START position, power is
transferred to terminal S, to the first small stud on the
solenoid, out the other side through the PTO and
neutral switches to ground for starting.
Содержание 991001-008
Страница 38: ...12 38 Figure 23 LP Low Pressure HP High Pressure FFBW Fluid Both Ways ...
Страница 40: ...12 40 Models 992013 014 015 016 PF2020 Figure 25 ...
Страница 54: ...13 54 Promaster 100 Kohler Command 50 Deck with Lift Models 991006 ...
Страница 59: ...13 59 Promaster 100 Kohler 16 18 HP ...
Страница 63: ...13 63 Promaster 100 Briggs Stratton ...
Страница 68: ...13 68 Model 992010 011 Briggs Stratton ...
Страница 75: ...13 75 Model 992015 016 Kohler 20 HP ...
Страница 76: ...13 76 Model 992301 Kohler 20 and 25 HP ...