![Gravely 991001-008 Скачать руководство пользователя страница 60](http://html1.mh-extra.com/html/gravely/991001-008/991001-008_service-manual_2258607060.webp)
13 - 60
Promaster 100 Kohler 16 -18 HP
Contact resistance is 0.1-0.3 ohms when correct.
Normally open switches, manually activated.
Contact resistance is 0.1-0.3 ohms when correct.
Normally open switches, manually activated.
Contact resistance is 0.1-0.3 ohms when correct.
Pins 85-86 coil. Resistance is 87-100 ohms.
Contact resistance is 0.1-0.3 ohms when correct.
Pins 30-87A normally closed, manually activated.
Ignition Switch
Off
Run
Start
Red (I)
12.00 Vdc
12.00 Vdc
12.00 Vdc
Light Blue (A)
12.00 Vdc
12.00 Vdc
Dark Blue (R)
12.00 Vdc
12.00 Vdc
Purple (B)
12.00 Vdc
12.00 Vdc
Brown (S)
12.00 Vdc
Hourmeter
Off
Run
Start
Black
12.00 Vdc
12.00 Vdc
White
To Ground
Right Interlock Switch
Off
Run
Start
Brown
12.00 Vdc
12.00 Vdc
Brown/White
12.00 Vdc
12.00 Vdc
Left Interlock Switch
Off
Run
Start
Brown
12.00 Vdc
12.00 Vdc
Brown/White
12.00 to ground
12.00 to ground
Relay
Off
Run
Start
Red and Green (86)
12.00 Vdc
12.00 Vdc
Black (87A)
Connected to ground circuit to engine kill
Green (30)
Connected to ground
Green (85)
Connected to ground through time delay
Содержание 991001-008
Страница 38: ...12 38 Figure 23 LP Low Pressure HP High Pressure FFBW Fluid Both Ways ...
Страница 40: ...12 40 Models 992013 014 015 016 PF2020 Figure 25 ...
Страница 54: ...13 54 Promaster 100 Kohler Command 50 Deck with Lift Models 991006 ...
Страница 59: ...13 59 Promaster 100 Kohler 16 18 HP ...
Страница 63: ...13 63 Promaster 100 Briggs Stratton ...
Страница 68: ...13 68 Model 992010 011 Briggs Stratton ...
Страница 75: ...13 75 Model 992015 016 Kohler 20 HP ...
Страница 76: ...13 76 Model 992301 Kohler 20 and 25 HP ...