Advanced Functions and Settings: AXIS ALIGNMENT - Axis Alignment Parameter Setting
90
between point 1 and point 2. The measured distance is shown on the 3
rd
row. Set
the actual distance on the 4
th
row.
• Press the RIGHT or LEFT ARROW key to move the cursor.
• Press the UP or DOWN key to increase or decrease the number for the distance
value.
• Press the ENTER key to store the setting.
The following menu appears:
Use the POSITION key to change the distance value to that of the printed
image, i.e., the distance between point 1 and point 3.
• Press the RIGHT or LEFT ARROW key to move the cursor.
• Press the UP or DOWN key to increase or decrease the number for the distance
value.
• Press the ENTER key to store the setting.
The following menu appears:
The light pointer or the loupe move back to the Axis Point 1.
If the Axis Point 1 is not the origin point of the pre-printed image, press the
POSITION key to move the light pointer or the loupe to the desired origin point for
cutting.
If the Axis Point 1 is the origin point of the pre-printed image, press the ENTER
key. Then press the ENTER key to store the setting. The READY menu appears,
the plotter is ready to start the cutting operation.
DISTANCE
POINT 1-3
00399.6 mm
.
OK?
..........
00400.0 mm
.
AXIS ORIGIN POINT
.
X=
...
mm
Y=
....
mm
CONDITION 1
.........
14
.
30
.
READY
.............
4
.
CB09Ux
...
0
.
Содержание FC5100-100
Страница 3: ......
Страница 19: ...Special Precautions Storing the Plotter 18 ...
Страница 27: ...Out of the Box Connecting the Plotter 26 ...
Страница 33: ...Cutters and Holders Blade Length 32 ...
Страница 65: ...Preparing to Cut Returning the Pen Carriage to Origin 64 ...
Страница 107: ...Advanced Functions and Settings RS 232C Serial Interface 106 ...
Страница 125: ...Background Settings Background Settings for HP GL 124 ...