Grandstream Networks, Inc.
DP715-US/DP710-US User Manual
Page
32 of 43
Firmware 0.0.0.8
Last Updated: 03/2012
Firmware File Postfix
Default is
blank
. End user should keep it blank.
Config File Prefix
Default is
blank
. End user should keep it blank.
Config File Postfix
Default is
blank
. End user should keep it blank.
Allow DHCP Option 66
to override server
If set to “Yes”, configuration and upgrade server information can be obtained using DHCP
option 66 from DHCP server located in customer’s environment. Default setting is
Yes.
Automatic Upgrade
Choose “
Yes”
to enable automatic upgrade and provisioning. If select “Check every
minutes” input the amount of minutes you want it to check for update. If select “Yes, daily
at hour” make sure to input the hour of the day you want it to check for update, e.g. for 11
pm type 23. If select “Yes, weekly on day” make sure you input the day of the week (in
format 0-6, 0 is Sunday) you want it to check for update. When set to No, DP715 will only
do the following option you select; “Always check for New Firmware at Boot up” will check
for new firmware every time the device reboots. “Check New Firmware only when F/W
pre/suffix changes” will check for updates only when the pre/suffix has been changed.
Authenticate Conf File
If set to Yes, config file is authenticated before acceptance. This protects the
configuration from an unauthorized change.
Firmware Key
Used for firmware encryption. Should be 32 digit in hexadecimal representation. End
user should keep it blank.
SSL Certificate
The user specify SSL certificate used for SIP over TLS in X.509 format.
SSL Private Key
The user specify SSL private key used for SIP over TLS in X.509 format.
SSL Private Key
Password
User specify password to protect the private key above.
ACS URL
User specify the Auto Configuration Server’s URL (TR-069 protocol)
ACS Username
User specify the ACS Username
ACS Password
User specify the ACS password
Periodic Inform
Enable
Default is
No
. If set to YES, device will send inform packets to the ACS
Periodic Inform
Interval
Frequency that the inform packets will be sent out to the ACS
Connection Request
Username
Set a user name for the ACS to connect to this device
Connection Request
Password
Set a password for the ACS to connect to this device
Call Progress Tones
Using these settings, users can configure tone frequencies and cadence according to
their preference. By default they are set to North American frequencies. Configure these
settings with known values to avoid uncomfortable high pitch sounds. ON is the period of
ringing (“On time” in ‘ms’) while OFF is the period of silence. In order to set a continuous
tone, OFF should be zero. Otherwise it will ring ON ms and a pause of OFF ms and then
repeat the pattern.
Example configuration for N.A. Dialtone:
f1=350@-13,f2=440@-13,c=0/0;
Syntax: f1=freq@vol, f2=freq@vol, c=on1/off1-on2/off2-on3/off3; [...]
(Note: freq: 0 - 4000Hz; vol: -30 - 0dBm)