50
temperature
CYCLE FUNCTIONS
SETTINGS
00/00°C
CYCLE 5
TIME
TEMPERATURE
PRE
WATER INLETS
WASH
WATER LEVEL
DRUM ACTION
COOLING
SPIN
DRAINING ACTION
TIME
7 minutes
TEMPERATURE
NONE
WATER INLETS
E4 , E5
WASH
WATER LEVEL
HIGH
DRUM ACTION
DELICATE
COOLING
NONE
SPIN
DRAINING ACTION
NONE
TIME
2 minutes
TEMPERATURE
Only cold water
RINSE
WATER INLETS
E5
1
WATER LEVEL
HIGH
DRUM ACTION
DELICATE
COOLING
NONE
SPIN
DRAINING ACTION
NONE
TIME
2 minutes
TEMPERATURE
Only cold water
RINSE
WATER INLETS
E5
2
WATER LEVEL
HIGH
DRUM ACTION
DELICATE
COOLING
NONE
SPIN
DRAINING ACTION
NONE
TIME
2 minutes
TEMPERATURE
Only cold water
RINSE
WATER INLETS
E4
3
WATER LEVEL
HIGH
DRUM ACTION
DELICATE
COOLING
NONE
SPIN
DRAINING ACTION
NONE
TIME
2 minutes
TEMPERATURE
Only cold water
RINSE
WATER INLETS
E4
4
WATER LEVEL
HIGH
DRUM ACTION
DELICATE
COOLING
NONE
SPIN
DRAINING ACTION
NONE
TIME
3 minutes
TEMPERATURE
Only cold water
RINSE
WATER INLETS
E1 , E5
5
WATER LEVEL
HIGH
DRUM ACTION
DELICATE
COOLING
NONE
FINAL SPIN
DRAINING ACTION
Drain and
1min.
500rpm spin
DISTRIBUTION
DRUM ACTION
DELICATE
E 1 =
SOLENOID VALVE
HARD WATERDISPENSER
E 2 =
SOLENOID VALVE
HOT WATER DISPENSER
E 3 =
SOLENOID VALVE
HOT WATER TUB
E 4 =
SOLENOID VALVE
HARD WATERTUB
E 5 =
SOLENOID VALVE
HARD WATERDISPENSER
ENGLISH