Repair
Transformer Primary Check
1. See
Shutdown, page 49
.
2. Locate the two smaller (10 AWG) wires, labeled
1 and 2, coming out of transformer. Trace these
wires back to terminal blocks TB23 and TB24.
Use an ohmmeter to test for continuitybetween
two wires; there should be continuity.
Transformer Secondary Check
1. See
Shutdown, page 49
.
2. Locate the two larger (6 AWG) wires, labeled 3
and 4, coming out of transformer. Trace these
wires back to circuit breaker CB20 (906). Open
the circuit breaker to turn the color indicator on
the circuit breaker GREEN. Use an ohmmeter to
test for continuitybetween two transformer wires
in circuit breaker terminals 1 and 3; there should
be continuity.
3. Close the circuit breaker CB20 (906).
Figure 27
4. Confirm main power switch is off before starting
generator.
5. Start the generator.
Press start button
twice on the engine
control module. The controller will automatically
sequence glow plug warming and crank
operations. Allow engine to reach full operating
speed.
Note
Engine will not start if main power switch
is in the on position.
6. Turn main power switch on.
7. Press
to turn on hose heat zone.
This equipment is used with heated fluid which
can cause equipment surfaces to become very
hot. To avoid severe burns:
• Do not touch hot fluid or equipment.
• Allow equipment to cool completelybefore
touching it.
• Wear gloves if fluid temperature exceeds
110°F (43°C).
• Do not turn on hose heat without fluid in
hoses.
Thermal expansion can cause
overpressurization, resulting in equipment
rupture and serious injury, including fluid
injection. Do not pressurize system when
preheating hose.
3A1706K
73
All manuals and user guides at all-guides.com
Содержание Reactor E-30i
Страница 91: ...Notes Notes 3A1706K 91 All manuals and user guides at all guides com a l l g u i d e s c o m ...
Страница 93: ...Parts 3A1706K 93 All manuals and user guides at all guides com ...
Страница 94: ...Parts 94 3A1706K All manuals and user guides at all guides com ...
Страница 102: ...Parts 102 3A1706K All manuals and user guides at all guides com ...
Страница 105: ...Parts 3A1706K 105 All manuals and user guides at all guides com ...
Страница 106: ...Parts 106 3A1706K All manuals and user guides at all guides com a l l g u i d e s c o m ...
Страница 107: ...Parts 3A1706K 107 All manuals and user guides at all guides com ...
Страница 118: ...Parts Air Control Panel 118 3A1706K All manuals and user guides at all guides com ...
Страница 153: ...Dimensions Pallet Mounting Dimensions Figure 57 3A1706K 153 All manuals and user guides at all guides com ...