Troubleshooting
Error
Code
Error
Location
Type
Name
Cause
Solution
T8AE
T8BE
Heat
Exchanger
ALARM
Temperature
Not Rising Hx
A (T8AE)
Temperature
Not Rising Hx
B (T8BE)
A and B heat
exchanger RTD cables
cross-connected to
splitter cable.
Swap RTD connections to
splitter 1 an 2 markings. See
Reactor Wiring Diagram,
page 144
.
Bad heater rod (boost).
Measure resistance, 23 – 26
Ω, of heater rod, replace if
reading open. See
Replace
Heater Element, page 68
.
Low chemical supply
temperature.
Recirculate heated chemical
back to drum in cold
conditions before spraying
chemical below 32°F(0°C)
at startup. Use Jog Mode for
heat exchanger heating.
T8DA
T8DB
Boost A
Boost B
ALARM
Temperature Not
Rising
Bad heated hose.
Measure hose resistance,
replace if reading open. See
Heated Hose manual for
repair.
Started spraying before
engine and hose reached
operating temperature.
Wait until operating
temperatures have been
reached on engine and hose
before spraying.
T8DH Hose
ALARM
Temperature Not
Rising
Low chemical supply
temperature.
Recirculate heated chemical
back to drum in cold
conditions before spraying.
Chemical below 32°F(0°C)
at startup.
V1CM MCM
ALARM
Bus Under
Voltage
Tripped MCM circuit
breaker (CB02).
Visuallycheck circuit
breaker for a tripped
condition. If Diagnostic
screen is enabled, MCM
Bus 14 V indicates normal
voltage and 1 V indicates
failed MCM.
Loose or bad connection. Check wiring for loose wires.
Low generator line
voltage
Measure voltage across
main power switch. Voltage
should measure between
190 and 264 VAC.
V1MH Hose
ALARM
Low Line Voltage
High auxiliaryinrush
current.
Ensure compressor or
air dryer are setup to be
continuous run and sized
according to manual.
3A1706K
27
All manuals and user guides at all-guides.com
Содержание Reactor E-30i
Страница 91: ...Notes Notes 3A1706K 91 All manuals and user guides at all guides com a l l g u i d e s c o m ...
Страница 93: ...Parts 3A1706K 93 All manuals and user guides at all guides com ...
Страница 94: ...Parts 94 3A1706K All manuals and user guides at all guides com ...
Страница 102: ...Parts 102 3A1706K All manuals and user guides at all guides com ...
Страница 105: ...Parts 3A1706K 105 All manuals and user guides at all guides com ...
Страница 106: ...Parts 106 3A1706K All manuals and user guides at all guides com a l l g u i d e s c o m ...
Страница 107: ...Parts 3A1706K 107 All manuals and user guides at all guides com ...
Страница 118: ...Parts Air Control Panel 118 3A1706K All manuals and user guides at all guides com ...
Страница 153: ...Dimensions Pallet Mounting Dimensions Figure 57 3A1706K 153 All manuals and user guides at all guides com ...