Troubleshooting
Problem
Cause
Solution
Hoses near Reactor are warm, but
hoses downstream are cold.
Shorted connection or failed hose
heating element.
With power off, check the hose
resistance with and without the
whip hose attached. With the whip
hose attached, the reading should
be less than 3 ohm. Without the
whip hose attached, the reading
should be OL (open loop). See
Check Hose Heat Connectors,
page 71
.
A and B temperature setpoints too
low.
Increase A and B setpoints. Hose
designed to maintain temperature,
not increase temperature.
Hose temperature setpoint too
low.
Check. Increase if necessaryto
maintain heat.
Flow too high.
Use smaller mix chamber.
Decrease pressure.
Low current; FTS not installed.
Install FTS, see operation manual.
Hose heat zone not turned on long
enough to reach setpoint.
Allow hose to heat up, or preheat
fluid.
Loose hose electrical connections. Check connections. Repair as
necessary.
Low hose heat.
Ambient temperature is to low
Relocate hoses to a warmer area
or increase A and B setpoints.
3A1706K
35
All manuals and user guides at all-guides.com
Содержание Reactor E-30i
Страница 91: ...Notes Notes 3A1706K 91 All manuals and user guides at all guides com a l l g u i d e s c o m ...
Страница 93: ...Parts 3A1706K 93 All manuals and user guides at all guides com ...
Страница 94: ...Parts 94 3A1706K All manuals and user guides at all guides com ...
Страница 102: ...Parts 102 3A1706K All manuals and user guides at all guides com ...
Страница 105: ...Parts 3A1706K 105 All manuals and user guides at all guides com ...
Страница 106: ...Parts 106 3A1706K All manuals and user guides at all guides com a l l g u i d e s c o m ...
Страница 107: ...Parts 3A1706K 107 All manuals and user guides at all guides com ...
Страница 118: ...Parts Air Control Panel 118 3A1706K All manuals and user guides at all guides com ...
Страница 153: ...Dimensions Pallet Mounting Dimensions Figure 57 3A1706K 153 All manuals and user guides at all guides com ...