Troubleshooting
Error
Code
Error
Location
Type
Name
Cause
Solution
Hose portion exposed
to an excessive heat
source, like hot sun or
coiled hose, can pass
fluid more than 27°F
(15°C) over temperature
setting to the FTS.
Shade exposed hose from
hot sun or expose FTS to
same environment when
at rest. Uncoil entire hose
before heating to avoid
self-heating.
T4DH Hose
ALARM
High Chemical
Temperature
Bad High Power
Temperature Control
Module.
Replace HPTCM. See
Replace High Power
Temperature Control
Module (HPTCM), page 86
.
Cooling fans are not
operating properly.
Ensure ambient temperature
is less than 120°F (48°C).
Check to see that the fans
are moving. Measure
voltage to fans. There
should be 240 VAC. If no
voltage is measured, check
wiring between fan and
circuit breaker CB03.
If the fans have voltage but
are not moving, replace fan.
Use an air hose to blow out
around the fan housings and
remove anybuilt-up debris.
T4NM MCM
ALARM
High Motor
Temperature
Bad electric motor.
Replace motor. See
Repair
Electric Motor, page 61
.
24
3A1706K
All manuals and user guides at all-guides.com
Содержание Reactor E-30i
Страница 91: ...Notes Notes 3A1706K 91 All manuals and user guides at all guides com a l l g u i d e s c o m ...
Страница 93: ...Parts 3A1706K 93 All manuals and user guides at all guides com ...
Страница 94: ...Parts 94 3A1706K All manuals and user guides at all guides com ...
Страница 102: ...Parts 102 3A1706K All manuals and user guides at all guides com ...
Страница 105: ...Parts 3A1706K 105 All manuals and user guides at all guides com ...
Страница 106: ...Parts 106 3A1706K All manuals and user guides at all guides com a l l g u i d e s c o m ...
Страница 107: ...Parts 3A1706K 107 All manuals and user guides at all guides com ...
Страница 118: ...Parts Air Control Panel 118 3A1706K All manuals and user guides at all guides com ...
Страница 153: ...Dimensions Pallet Mounting Dimensions Figure 57 3A1706K 153 All manuals and user guides at all guides com ...