Operation Using a Programmable Logic Controller (PLC)
Network
Network
Network
Output
Output
Output ID
ID
ID
Modbus
Modbus
Modbus
Register
Register
Register
Parameter
Parameter
Parameter Name
Name
Name
Data
Data
Data Type
Type
Type
Units
Units
Units
Range
Range
Range
0010
41020
Actual Pump 1 Flow
Rate
uint32
cc/min
0 – 800
0011
41022
Actual Pump 2 Flow
Rate
uint32
cc/min
0 – 800
0012
41024
Actual Pump 1 Fluid
Pressure
uint32
PSI
0 – 1500
0013
41026
Actual Pump 2 Fluid
Pressure
uint32
PSI
0 – 1500
0014
41028
Active Recipe Number
uint32
NONE
0 – 30, 61
0015
41030
Active Recipe Material
A
uint32
NONE
1 – 32, 61
0016
41032
Active Recipe Material
B
uint32
NONE
33 – 40, 61
0017
41034
Active Recipe Material
A Flush Sequence
uint32
NONE
1 – 5
0018
41036
Active Recipe Material
B Flush Sequence
uint32
NONE
1 – 5
0019
41038
Active Recipe Ratio
Set Point
uint32
NONE
0 – 5000
0020
41040
Active Recipe Potlife
Time Set Point
uint32
min
0 – 999
0021
41042
Job Number
uint32
NONE
0 – 9999
0022
41044
Job A Sprayed Volume
unit32
cc
0 – 999999999
0023
41046
Job B Sprayed Volume
unit32
cc
0 – 999999999
0024
41048
Job Solvent Volume
unit32
cc
0 – 999999999
0 = Open
0025
41050
Safety Interlock Input
Status
unit32
NONE
1 = Closed
1 = Pump Off
2 = Color Change
3 = Color Change: Purge A
4 = Color Change: Purge B
5 = Color Change: Fill
6 = Mix Fill
7 = Mix
8 = Mix Idle
9 = Purge A
10 = Purge B
11 = Standby: Mix Ready
12 = Standby: Fill Ready
13 = Standby: Mix Not Ready
14 = Standby: Alarm
15 = Line Filling/Flushing
16 = Pump Prime/Flush
0026
42000
Current System Mode
uint32
NONE
17 = Maintenance/Calibration
32
3A4486D