Catalyst
Catalyst
Catalyst (B)
(B)
(B) Valve
Valve
Valve (Disabled
(Disabled
(Disabled in
in
in 1K
1K
1K Mode)
Mode)
Mode)
Enter the desired catalyst valve number (1-8).
NOTE:
NOTE:
NOTE: If you enter a number which is not valid in
your system configuration, the field will be highlighted
and the recipe is invalid. For example, if your
configuration has 1 catalyst valve and you enter 4,
the field will be highlighted and the recipe is invalid.
Figure 48 Invalid Recipe Screen
Mix
Mix
Mix Ratio
Ratio
Ratio (Disabled
(Disabled
(Disabled in
in
in 1K
1K
1K Mode)
Mode)
Mode)
Enter the desired mix ratio (0 to 50.0):1.
Potlife
Potlife
Potlife Time
Time
Time
Enter the potlife time (0 to 999 minutes). Entering
0 disables this function.
Target
Target
Target Pressure/Flow
Pressure/Flow
Pressure/Flow
Enter the desired target spray pressure or flow rate,
depending on whether the Mix Unit is configured for
Pressure Control or Flow Control (see Fluid Control
on System Screen 4). This is the pressure or flow
rate the pumps will maintain while mixing. This field
is only available when the Flow Control is set to
‘Recipe’ (see Flow Control on System Screen 4).
Mix
Mix
Mix Pressure
Pressure
Pressure Tolerance
Tolerance
Tolerance (Disabled
(Disabled
(Disabled in
in
in 1K
1K
1K
Mode)
Mode)
Mode)
The pressure of one component must be within
a percentage (±) of the pressure of the other
component during spray or mix. Set the desired Mix
Pressure Tolerance in this field. The default is 25%.
3A4486D
77