Operation Using a Programmable Logic Controller (PLC)
Network
Network
Network
Input
Input
Input ID
ID
ID
Modbus
Modbus
Modbus
Register
Register
Register
Parameter
Parameter
Parameter Name
Name
Name
Data
Data
Data
Type
Type
Type
Units
Units
Units
Range
Range
Range
0 = No OP
1 = Power Pumps
2 = Remote Stop
3 = Color Change
4 = Mix Fill
5 = Mix
6 = Purge A
7 = Purge B
8 = Standby
0010
42100
System Mode Command
uint32
NONE
9 = Recipe Purge
0011
42102
Clear Active Alarm/Deviation
uint32
NONE
1 = Clear Active Alm/Dev
0012
42104
Goto Recipe Number
uint32
NONE
0, 1 – 30
0013
42106
Mix Control Set Point
uint32
cc/min or
PSI
1 - 1600
0014
42108
Mix Fill Set Point
unit32
cc/min or
PSI
1 – 1600
0015
42110
Pump Flush Sequence #/Prime
Material #
unit32
NONE
1 –5, 1 – 40
0 = No OP
1 = Flush Pump 1
2 = Prime Pump 1
3 = Flush Pump 2
4 = Prime Pump 2
5 = Flush Pump 3
6 = Prime Pump 3
7 = Flush Pump 4
8 = Prime Pump 4
9 = Fill Line
10 = Flush Line
0016
42112
Flush/Prime Pump Command
unit32
NONE
11 = Stop Line Fill/Flush
0017
42114
Job Complete
unit32
NONE
1 = Trigger job complete
0 = Gun not triggered
0018
42116
Gun 2 Trigger
unit32
NONE
1 = Gun triggered
0 = Flow Control
0019
42118
Fluid Control Mode
unit32
NONE
1 = Pressure Control
0020
43100
Command Argument 1
unit32
NONE
N/A
0021
43102
Command Argument 2
unit32
NONE
N/A
0022
43104
Command Argument 3
unit32
NONE
N/A
0023
43106
Command Argument 4
unit32
NONE
N/A
0024
43108
Command Argument 5
unit32
NONE
N/A
0025
43110
Command Argument 6
unit32
NONE
N/A
40