Miscellaneous
Miscellaneous
Miscellaneous Errors
Errors
Errors
NOTE:
NOTE:
NOTE: In some error codes listed below, a # symbol is shown as the last digit. This symbol represents the applicable
component number, which can vary. The unit’s display will show the applicable number as the last digit in the
code. For example, the B9D# code listed in this table will be displayed as B9D1 if the affected component is pump
1, B9D2 for pump 2, and so on.
Code
Code
Code
Type
Type
Type
Description
Description
Description
Problem
Problem
Problem
Cause
Cause
Cause
Solution
Solution
Solution
B9A#
Advisory
Volume
Rollover A
Current Mix
Unit #
Batch counter for
material A rolled over
for Mix Unit #.
The totalizer has
reached maximum
capable value and
started over at zero.
n/a
B9AX
Advisory
Volume
Rollover A
Lifetime
Grand total counter for
material A rolled over.
The totalizer has
reached maximum
capable value and
started over at zero.
n/a
B9B#
Advisory
Volume
Rollover B
Current Mix
Unit #
Batch counter for
material B rolled over
for Mix Unit #.
The totalizer has
reached maximum
capable value and
started over at zero.
n/a
B9BX
Advisory
Volume
Rollover B
Lifetime
Grand total counter for
material B rolled over.
The totalizer has
reached maximum
capable value and
started over at zero.
n/a
B9D#
Advisory
Volume
Rollover Pump
#
Grand total counter for
pump # rolled over.
The totalizer has
reached maximum
capable value and
started over at zero.
n/a
B9S1
B9S2
Advisory
Volume
Rollover
Solvent
Current Mix
Unit #
Batch counter for
solvent rolled over for
Mix Unit 1 (1) or Mix
Unit 2 (2).
The totalizer has
reached maximum
capable value and
started over at zero.
n/a
B9S3
B9S4
Advisory
Volume
Rollover
Solvent
Lifetime
Grand total counter for
solvent rolled over for
Mix Unit 1 (3) or Mix
Unit 2 (4).
The totalizer has
reached maximum
capable value and
started over at zero.
n/a
WX00
Alarm
Software
Errors
An unexpected
software error has
occurred.
Call Graco technical
support.
Calibration
Calibration
Calibration Errors
Errors
Errors
NOTE:
NOTE:
NOTE: In some error codes listed below, a # symbol is shown as the last digit. This symbol represents the applicable
component number, which can vary. The unit’s display will show the applicable number as the last digit in the
code. For example, the ENT# code listed in this table will be displayed as ENT1 if the affected component is pump
1, ENT2 for pump 2, and so on.
Code
Code
Code
Type
Type
Type
Name
Name
Name
Description
Description
Description
END#
Record
Calibration Pump #
A calibration test was run on the pump.
ENS#
Record
Calibration Solvent Meter #
A calibration test was run on the solvent
meter.
ENT#
Record
Calibration Stall Test Pump #
A stall test was completed successfully on
pump #.
3A4486D