Operation Using a Programmable Logic Controller (PLC)
Network
Network
Network Input
Input
Input Data
Data
Data Map
Map
Map (Write/Read)
(Write/Read)
(Write/Read)
Network
Network
Network
Input
Input
Input ID
ID
ID
Modbus
Modbus
Modbus
Register
Register
Register
Parameter
Parameter
Parameter Name
Name
Name
Data
Data
Data
Type
Type
Type
Units
Units
Units
Range
Range
Range
0 = No OP
1 = Power Pumps
2 = Remote Stop
3 = Color Change
4 = Mix Fill
5 = Mix
6 = Purge A
7 = Purge B
8 = Standby
9 = Recipe Purge
0000
41100
System Mode Command
uint32
NONE
10 = Solvent Push
0001
41102
Clear Active Alarm/Deviation
uint32
NONE
1 = Clear Active Alm/Dev
0002
41104
Goto Recipe Number
uint32
NONE
0, 1 – 30
0003
41106
Mix Control Set Point
uint32
cc/min
PSI
1 - 1600
0004
41108
Mix Fill Set Point
unit32
cc/min or
PSI
1 – 1600
0005
41110
Pump Flush Sequence #/Prime
Material #
unit32
NONE
1 –5, 1 – 40
0 = No OP
1 = Flush Pump 1
2 = Prime Pump 1
3 = Flush Pump 2
4 = Prime Pump 2
5 = Flush Pump 3
6 = Prime Pump 3
7 = Flush Pump 4
8 = Prime Pump 4
9 = Fill Line
10 = Flush Line
0006
41112
Flush/Prime Pump Command
unit32
NONE
11 = Stop Line Fill/Flush
0007
41114
Job Complete
unit32
NONE
1 = Trigger job complete
0 = Gun not triggered
0008
41116
Gun 1 Trigger
unit32
NONE
1 = Gun triggered
0 = Flow Control
0009
41118
Fluid Control Mode
unit32
NONE
1 = Pressure Control
3A4486D
39