Appendix B
86
309738L
Run Screen (Batch Dispense Mode)
The purpose of this screen is to display the required run parameters.
Notes:
1.
Reverse image indicates Run Mode Bead scale is enabled in the setup
other screen.
2.
Target volume should change based on style.
3.
Error values reflect the last completed job’s data.
Description
Possible Values
Default Value
Hour
0-23
N/A
Minute
0-59
N/A
Day
1-31
N/A
Month
1-12
N/A
Year
2000-2099
N/A
Date Format
mm/dd/yy-dd/mm/yy
mm/dd/yy
Pressure
0-9999
N/A
Pressure Units
psi or bar
psi
Actual Flow Rate
0-9999 cc/min
N/A
Command
0-100%
N/A
Bead Scale
note 1
50-150%
100%
Dispense Mode
Auto or Manual
N/A
Control Mode
Bead Control, Volume Monitor,
Batch Dispense, or Pressure
Control
Bead Control
Style
1 to 4
1
Target Volume
note 2
0 to 9999.9 cc
25.0 cc
Actual Volume
0 to 9,999,999.9 cc
N/A
Volume Error
note 3
-100.0 to 999.9%
N/A
Active Fault
Numerous text strings
N/A
Output:
345 psi
213 cc/min
Command: 100%
% Bead Scale
Mode:
Auto
Batch Dispense
VOLUME:
Target:
414 cc
Measured
- 0.5%
No Active Faults
09/06/02 10:00
112
412
Содержание 234129
Страница 3: ...List of Models 309738L 3...
Страница 26: ...PrecisionFlo LT Module Operation 26 309738L...
Страница 53: ...Software Upgrade 309738L 53 Control Board FIG 22 253613 flash memory chip Beveled edge...
Страница 107: ...Appendix D 309738L 107...