Configuring Software
309738L
37
Setting User Variables
The following variables and presets should be verified prior to calibration and path programming and/or operation in
automatic mode. All of the screens as well as additional screen information can be viewed in
,
, starting on page 84.
There are additional variables that should be set after the path programming is completed, they include; High/Low
pressure settings and Style (volume) information.
Table 5 - PrecisionFlo LT User Variables and Presets
Values in italics are factory defaults.
Other System Variables
After the calibration and automation path programming is complete and the desired bead profiles have been
achieved, verify that the following variables are set.
Table 6 - PrecisionFlo LT System Variables
Screen
Variable / Preset
Values
Comments
Dispense
Control Mode
Bead Control
, Volume Monitor,
Batch Dispense, or pressure
control
Only bead control mode controls flow.
Other
Command Mode
Analog
or Fixed
Job End Mode
Timer or
Digital
I/O
Language
Many
Set the desired language.
Pressure Units
psi
or bar
Set the desired pressure units.
Manual Gun Flow
Rate
0 - 100%,
50%
Flow rate or pressure setting for Manual
Dispense.
Job End Delay
0 - 999 sec,
4 sec
Delay time after dispensing for job com-
plete if Job End Mode is set to Timer.
Year, Month, Day,
Hour, Minute
Set the Time and Date.
Default / Fixed
Command
0-100%,
50%
Set value for fixed command mode. If the
command signal falls below 1 VDC in ana-
log mode, this value will be used as the
command.
Screen
Variable / Preset
Values
Comments
Dispense
Volume
0 - 9999 cc,
25 cc
Set the volume set point for each of the styles being used.
Tolerance
0 - 99.9%,
10%
Set the volume tolerance for each of the styles being used.
Other
Set the User configurable faults to Alarms or Warnings. More information on the faults can be found in
PrecisionFlo LT User Interface
An Alarm will cause the fault present signal to activate and the dispenser ready signal to drop out. This
is something considered by the user to be a major fault, one which should cause the system to stop
dispensing.
A Warning will cause the fault present signal to activate and the dispense ready signal to stay on. This
is something considered by the user to be a minor fault, one which will warn the user but will continue
dispensing even if the bead profile is degraded.