Setup Screen 2: Calibrate Screen (Batch Dispense and Volume Monitor Modes)
Notes:
1.
The values for the pressure loop constants Kp and Ki can also be directly entered by the user in the OTHER
setup screen.
100% Command Flow
psi
In Manual Mode, press
to begin calibration
Calibration required (valid)
Press
to see details
Output
1254 psi
Desired Output
1250 psi
Result
Kp 105
Ki 4
Max System Output
3250 psi
3405 cc/min
Dispense
Calibrate
Other
No Active Faults
09/06/02 10:00
2500
Description
Possible Values
Default Value
Hour
0-23
N/A
Minute
0-59
N/A
Day
1-31
N/A
Month
1-12
N/A
Year
2000-2099
N/A
Date Format
mm/dd/yy-dd/mm/yy
mm/dd/yy
100% commanded pressure
1 to 9999
1000
Calibration status
In process, complete
N/A
Pressure
0-9999
N/A
Pressure Units
psi or bar
psi
Desired Outlet Pressure
0 - 9999
N/A
Calculated optimal Kp
note 1
0 to 9999
100
Calculated optimal Ki
note 1
0 to 9999
6
System maximum pressure with completely
open reg
0 to 9999
N/A
System maximum flow with completely open
reg
0 to 9999
N/A
Active Fault
Numerous text strings
N/A