Appendix B
309738L
91
Setup Screen 2: Calibrate Screen (Pressure Control Mode)
Notes:
1.
The values for the pressure loop constants Kp and Ki can also be directly entered by the user in the OTHER
setup screen.
100% Command Pressure
psi
In Manual Mode, press
to begin calibration
Calibration required (valid)
Press
to see details
Output 1254 psi
Desired Output 1250 psi
Result
Kp 105
Ki 4
Max System Output
3250 psi
Dispense
Calibrate
Other
No Active Faults
09/06/02 10:00
2500
Description
Possible Values
Default Value
Hour
0-23
N/A
Minute
0-59
N/A
Day
1-31
N/A
Month
1-12
N/A
Year
2000-2099
N/A
Date Format
mm/dd/yy-dd/mm/yy
mm/dd/yy
100% commanded pressure
1 to 9999
1000
Calibration status
In process, complete
N/A
Pressure
0-9999
N/A
Pressure Units
psi or bar
psi
Desired Outlet Pressure
0 - 9999
N/A
Calculated optimal Kp
note 1
0 to 9999
100
Calculated optimal Ki
note 1
0 to 9999
6
System maximum pressure with com-
pletely open reg
0 to 9999
N/A
Active Fault
Numerous text strings
N/A
Содержание 234129
Страница 3: ...List of Models 309738L 3...
Страница 26: ...PrecisionFlo LT Module Operation 26 309738L...
Страница 53: ...Software Upgrade 309738L 53 Control Board FIG 22 253613 flash memory chip Beveled edge...
Страница 107: ...Appendix D 309738L 107...