PrecisionFlo LT Module Operation
309738L
25
PrecisionFlo LT Module Operation
Reading PrecisionFLo LT Control / Indicators
Table 2 - PrecisionFlo Buttons/Switches
Table 3 - PrecisionFlo LT Indicators
Table 4 - PrecisionFlo Indicator Lights
F
IG
. 11
7
6
4
3
1
2
Ref
Button/Switch
What it Does
4
Sealer Stop Button
•
Disables all air solenoids and V/P regulators.
•
Signals the external controller that a SEALER STOP condition is in effect.
6
Run/Setup Mode Key
Switch
•
Turn key switch counter-clockwise to set control unit to Run Mode. When the
key is in Run Mode or removed, you can operate and monitor the system.
•
Turn key switch clockwise to set control unit to Setup Mode (for software con-
figuration). The key cannot be removed while turned to Setup Mode.
7
Main Electrical Power
(Disconnect) Switch
•
Turns on power to system.
•
Lights Condition Light(s).
Ref
Indicator
Indicator
light
Meaning
1
User Display
On
Display is on when power is applied to the control assembly.
Off
Display is off when power is removed from the control assembly or
the screen saver is active. Press any key to activate the screen.
Dispenser Ready
Light (Ref 2) Status
Fault Present Light
(Ref 3) Status
Off
Off
No System Power or the system is in manual mode with no fault
present.
On
Off
System is in auto mode with no fault present.
On
On
System is in auto mode with a minor fault present.
Off
On
System is in auto or manual mode with a major fault present or
the system is in manual mode with a minor fault present.