Troubleshooting and Fault Recovery
309738L
49
Table 9 - Fault Priority Table
(continued)
Fault
Priority
Fault Name
Fault Description
Causes
Solutions
9
Low Outlet
Pressure
Output pressure of the
PrecisionFlo LT regulator
is below the limit set for
operation. If this fault
occurred while doing a
pressure calibration, sys-
tem pressure was too
low (<500 psi [3.4MPa,
34 bar] at the regulator
outlet) to complete the
calibration
Incorrect limit set
Verify limit is set correctly
No or insufficient material flow
Increase material flow rate
Dispense valve needle is stuck
closed
Dislodge and inspect needle
Dispense valve leaking
Repair dispense valve
Regulator not operating properly
Repair regulator
Pump wink passed through outlet
Recalibrate PrecisionFlo LT or
increase pump pressure
Failed transducer
Check transducer, replace if failed
Incorrect pressure amplification
switch setting
Verify switch is set correctly
10
High Volume
Material dispensed dur-
ing the last dispense
cycle was above the
amount established by
request and above the
allowable (entered) toler-
ance
Material viscosity is outside flow
compensation window
Verify material characteristics,
recalibrate if necessary. Increase
Bead scale
PrecisionFlo LT regulator is not
regulating properly
Check regulator, repair if neces-
sary. Increase pressure to regula-
tor above.
Incorrect volume or tolerance
when using Volume Monitor or
Batch Dispense
Enter correct values or minimum
operating pressure
11
Low Volume
Material dispensed dur-
ing the last dispense
cycle was below the
amount established by
request and below the
allowable (entered) toler-
ance
Partially plugged tip or supply
system. Error is outside flow com-
pensation window
Clean tip and/or supply system.
Insufficient flow to PrecisionFlo LT
regulator inlet. Error is outside
flow compensation window
Increase flow rate to PrecisionFlo
LT regulator inlet
Material viscosity is outside flow
compensation window
Verify material characteristics,
recalibrate if necessary
Material viscosity increased
Increase bead scale
PrecisionFlo LT regulator is not
regulating properly
Enter correct values or set the tol-
erance to 0% to disable this fault
12
Low Flow
Rate
Measured flow rate less
than desired flow rate
minus tolerance
Fluid supply too low to achieve
desired flow rate
Increase fluid supply pressure or
check for clogged filter
Tip plugged
Clean/replace tip
No air pressure to solenoid valves
Turn on air to solenoid valves
No flow meter signal
Check cable and sensor
No material supply
Replace drum or turn on pumps
Incorrect flow tolerance or flow
fault time
Enter correct tolerance or flow fault
time