Graco Standard Warranty

332462A

33

Graco Standard Warranty

Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from defects in 
material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty 
published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by 
Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco’s written 
recommendations.

This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty 
installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of 
non-Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of Graco equipment with 
structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, installation, operation or 
maintenance of structures, accessories, equipment or materials not supplied by Graco.

This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification of 
the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be returned 
to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or workmanship, repairs will 
be made at a reasonable charge, which charges may include the costs of parts, labor, and transportation.

THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED 
TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE

Graco’s sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other remedy 
(including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or 
consequential loss) shall be available. Any action for breach of warranty must be brought within two (2) years of the date of sale.

GRACO MAKES NO WARRANTY, AND DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A 
PARTICULAR PURPOSE, IN CONNECTION WITH ACCESSORIES, EQUIPMENT, MATERIALS OR COMPONENTS SOLD BUT NOT 
MANUFACTURED BY GRACO

. These items sold, but not manufactured by Graco (such as electric motors, switches, hose, etc.), are subject to 

the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these 
warranties.

In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment hereunder, or 
the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract, breach of warranty, the 
negligence of Graco, or otherwise.

FOR GRACO CANADA CUSTOMERS

The Parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings entered into, 
given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnaissent avoir convenu que la 
rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires exécutés, donnés ou intentés, à la suite 
de ou en rapport, directement ou indirectement, avec les procédures concernées.

Graco Information

For the latest information about Graco products, visit www.graco.com.

TO PLACE AN ORDER, 

contact your Graco distributor or call 1-800-690-2894 to identify the nearest distributor.

Содержание 16V133

Страница 1: ...eeder For professional use only Model 16V133 120V Vibratory Parts Feeder for separating and presenting parts Important Safety Instructions Read all warnings and instructions in this manual Save these...

Страница 2: ...um Output of Control 13 Soft Start 13 CFR Positive and Negative Gain 13 Frequency Settings 13 Resonate Threshold Level 14 AutoTrack Dead Band 14 Diagnostics 14 Security Settings 14 Default Memory 14 L...

Страница 3: ...d comply with all local codes and regula tions EQUIPMENT MISUSE HAZARD Misuse can cause death or serious injury Do not operate the unit when fatigued or under the influence of drugs or alcohol Check e...

Страница 4: ...n Ref Description A Parts Table Left Half K M12 Connector B Parts Table Right Half L Fuses C Adjustable Gate M Hopper Feed Table D Parts Hopper N Electromagnet Left Half E Lifting Points P Electromagn...

Страница 5: ...red location The G Flex 1500 Floor Mounting Plate J is designed to be anchored using four 3 8 in con crete anchor bolts 3 Use a concrete drill bit of the size recommended by the anchor bolt manufactur...

Страница 6: ...secure and install the cover on the junction box PLC Interface The G Flex 1500 is designed to be PLC controlled through the M12 5 Pin connector Refer to the M12 Pin Diagram for details about the M12 c...

Страница 7: ...sonate frequency it can maintain the resonate frequency and amplitude as the parts load changes See Start Up Procedure page 8 for Auto Scan Set Up Key Function ENTER Allows entry to menu and access to...

Страница 8: ...e frequency is between 60 67Hz If it falls outside of this range see Trou bleshooting page 23 11 With the table running press and hold the DOWN ARROW key until the amplitude is set to a value of 0 0 C...

Страница 9: ...eys to dial in on the desired feed rate This directly changes the CFR Value 5 Once the feed rate is determined record the CFR value of the part for future reference on the CFR Value table provided on...

Страница 10: ...Value table provided on page 31 NOTE The chart below illustrates a general rule for operating the G Flex 1500 Parts with less surface area and more mass will require a greater CFR to move parts around...

Страница 11: ...r Restores User Settings 1 Restore Settings 2 Enter Restores User Settings 2 Restore Settings 3 Enter Restores User Settings 3 Save Settings 1 Enter Saves User Settings 1 Save Settings 2 Enter Saves U...

Страница 12: ...ed output level rather than starting abruptly The soft start setting can be found under Power Settings menu The soft start can be set from 0 0 to 10 0 seconds Factory default is 0 Changing the soft st...

Страница 13: ...and increasing the settings makes the dead band range larger before a reaction takes place This setting normally does not need to be changed Diagnostics The first menu item under the diagnostic menu...

Страница 14: ...tart the con trol The operator should also monitor the temperature of the coils on the vibratory feeder The coils should never be too hot to hold CFR Set Point The CFR set point sets the amplitude vib...

Страница 15: ...een the tables This includes the brush that is connected to the tables Table Adjustment 1 Loosen the top two bolts of all four spring packs Adjust the table to minimum spacing 2 Ensure tables are leve...

Страница 16: ...to Scan page 7 Spring Replacement Table 1 Remove screws 44 holding spring pack 30 24 26 25 2 Remove and replace spring pack replace screws hand tighten only 3 Level table front to back and left to rig...

Страница 17: ...wire clamps holding wire to pedestal pull wire through pedestal 5 Remove screws 47 from electromagnet 29 6 Take electromagnet out of unit 7 Replace electromagnet Ensure there is an air gap of 090 bet...

Страница 18: ...en strain relief and remove wire from con trol panel area 4 Remove wire clamps holding wire to hopper Pull wire through hopper frame 5 Remove screws 4 and nuts 15 that attach elec tromagnet 13 to moun...

Страница 19: ...tach display panel 12 Connect power Display Keypad Replacement 1 Disconnect power to the unit See Power Discon nect page 15 2 Remove screws 3 from panel 11 3 Remove switch housing on harness 75 from b...

Страница 20: ...d wire 73 6 Disconnect ribbon cables from membrane switch on control board 2 places 7 Disconnect ribbon cable from display connector on control board 2 places 8 Replace display panel 9 Reverse steps f...

Страница 21: ...from control panel area 5 Loosen wire clamp and pull wire through pedestal Remove wire from corrugated sleeving 6 Remove screws 19 holding accelerometer 69 to table mounting bar 27 7 Replace accelero...

Страница 22: ...m control panel area 5 Loosen wire clamp Wire to be removed from corru gated sleeving 6 Remove screws 19 holding accelerometer 18 to hopper parts feed tray 7 7 Replace accelerometer 18 tighten screws...

Страница 23: ...the hook and loop Bolts holding spring packs together are not properly torqued Torque all bolts holding spring packs together to proper value Bolts holding tray to spring pack assembly are not properl...

Страница 24: ...24 24 25 25 25 24 24 24 24 26 26 24 24 24 24 27 28 102 30 23 29 37 36 32 33 19 19 58 58 59 59 40 101 38 100 39 39 42 43 104 44 103 44 47 55 82 83 60 61 45 46 86 87 93 92 63 64 90 64 65 89 24 94 95 96...

Страница 25: ...TRIP reclosable fastener a 2 59 16V558 STRIP reclosable fastener b 2 60 260067 FITTING strain relief 1 2 npt 7 61 117625 NUT locking 3 63 119695 DAMPENER engine mount 4 64 108851 WASHER plain 8 65 101...

Страница 26: ...Parts 26 332462A 20 21 4 48 56 11 3 12 16 80 17 45 51 51 60 61 66 3 68 13 70 91 76 81 67 67 5 6 6 7 8 8 8 8 6 6 9 9 9 9 10 10 10 10 108 88 19 18 97 97 98 11a 11a 88 88 ti22054a...

Страница 27: ...8 20 16V371 GATE hopper flex feeder paint 1 21 16V355 KNOB 5 prong 1 4 20 f 1 45 110755 WASHER plain 6 48 110141 SCREW cap sch 4 51 102040 NUT lock hex 8 56 16V888 LABEL branding g flex 1500 1 60 260...

Страница 28: ...TE BLACK GREEN WHITE BLACK BLACK WHITE BLUE BLACK WHITE BLUE BROWN BLUE BROWN BLUE GREEN WHITE BLACK GREEN GREEN BLACK BLACK WHITE WHITE GREEN BLACK WHITE GREEN GREEN WHITE BLACK GREEN GRAY TO TABLE D...

Страница 29: ...tic 2 69 16V820 SENSOR accelerometer table 1 70 16V827 CONNECTOR M12 5 pin 1 71 16V826 HARNESS fuse 1 73 16V823 HARNESS ground display 1 74 16V822 HARNESS power jumper table 1 75 16V821 HARNESS wire m...

Страница 30: ...l Board Table Coil Main Harness Fuse Ground Bar Hopper Coil Hopper Sensor Control Board Ref Part Description Qty 17 16V775 HOLDER fuse 2 29 16V272 COIL electromagnetic 2 69 16V820 SENSOR accelerometer...

Страница 31: ...CFR Values Table 332462A 31 CFR Values Table Part Reference Auto Track Mode Manual Mode CFR Value Frequency Amplitude...

Страница 32: ...39 4 cm x 61 0 cm Maximum Part Size 3 in x 3 in x 1 5 in 7 6 cm x 7 6 cm x 3 8 cm Maximum Weight capacity on table 30 lbs 13 6 kg ElectroMagnet Air Gap 090 inches 2 28mm Operating Voltage 120V 120V T...

Страница 33: ...TIES EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE Graco s sole obligation and buyer s sole remedy for any breach of warra...

Страница 34: ...Graco reserves the right to make changes at any time without notice This manual contains English MM 332462 Graco Headquarters Minneapolis International Offices Belgium China Japan Korea GRACO INC P O...