Repair
Power Disconnect
Prior to performing any repair procedure the power to
the unit must be disconnected at the main power source
(breaker box, hard wire plug).
Air Gap Specifications
The G-Flex arrives from the factory with certain air gaps
specifically designed for optimum performance. Make
sure the dimensions shown below are maintained after
installation or any time a repair or adjustment is made.
Table and Brush Spacing
The two tables on the G-Flex 1500 need to move inde-
pendent of each other for optimal operation. It is impor-
tant to keep a minimum of .020 in. spacing between the
tables. This includes the brush that is connected to the
tables.
Table Adjustment
1.
Loosen the top two bolts of all four spring packs.
Adjust the table to minimum spacing.
2.
Ensure tables are level with each other.
3.
When tables are level and spaced correctly, torque
all bolts to 150±10 in-lb.
4.
If a spacing adjustment has been made to the
tables, perform an
Auto Scan
, page 7.
Brush Adjustment
1.
If brushes are touching each other from one tray to
the other, remove the brush by peeling it off the
table.
2.
Confirm there is a minimum .020 in. spacing
between the tables.
3.
Install the brushes so they are lined up just to the
edge of their respective table.
4.
If a spacing adjustment has been made to the
tables, perform an
Auto Scan
, page 7.