Repair
332462A
21
Accelerometer Replacement
Table
1.
Disconnect power to the unit. See
Power Discon-
nect
, page 15.
2.
Remove screws (3) and display panel (11). See
Dis-
play (Keypad) Replacement
Procedure, page 19
3.
Disconnect sensor wires (69) from table control
board (80).
4.
Loosen strain relief and remove wire from control
panel area.
5.
Loosen wire clamp and pull wire through pedestal.
Remove wire from corrugated sleeving.
6.
Remove screws (19) holding accelerometer (69) to
table mounting bar (27).
7.
Replace accelerometer (69), tighten screws (19) to
25-30 in-lbs.
8.
Replace wire. Ensure wire is routed in protective
sleeving through strain relief.
9.
Replace wire clamps.
10. Attach wire to control board.
11. Tighten strain relief.
12. Replace display panel and screws.
BROWN
BLUE
ti22039a
ti22025a
ti22032a
ti22033a
ti22038a