Operation
332462A
11
Control Menu Layout
Main Menu
Sub Menu
Adjustments
Power Settings
Amplitude
[
0.0
to 100.0 ]%
Max Amplitude
[
100.0
to 40.0 ]%
Min Amplitude
[
0.0
to 95.0 ]%
Soft Start Time
[ 0.0 to 10.0 ] Seconds (
0.0
Default)
Amplitude Source
[
Auto Tracking
Manual, 0-10V, 4-20mA ]
**Auto Tracking or Manual only on G-Flex 1500
CFR Positive Gain
[
25
Default ]
CFR Negative Gain
[
5
Default ]
Frequency Settings
Frequency
[ 5.0 to 140.0 ] Hz (
60.0
Hertz Default)
Max Frequency
[ 15.0 to 140.0 ] Hz (
140.0
Hertz Default)
Min Frequency
[ 5.0 to 130.0 ] Hz (
45.0
Hertz Default)
Frequency Mode
[
Auto Tracking
, Manual ]
Auto Scan
[ Press ENTER to perform an automatic frequency scan ]
Resonate Threshold Level [
200
Default ]
Auto Track Dead Band
[
64
Default ]
Timer Settings
On Delay
[ 0.0 to 20.0 ] Seconds (
0.0
Default)
Off Delay
[ 0.0 to 20.0 ] Seconds (
0.0
Default)
Empty Bowl Timer
[ 5 to 255 ] Seconds (
10
Default) **Not used on G-Flex 1500
Power Key Interface
Sensor Polarity
[
Inverted
, Normal ]
Sensor Type
[
Auto
, NPN, PNP ]
Run Mode
[
Normal
, Always On, 2-Speed, High/Low ]
Empty Bowl
[
Normal
, Stop ] **Not used on G-Flex 1500
Aux Output Mode
[
Normal
, Inverted, Alarm, Inv Alarm, Air Jet ] **Not used on G-Flex 1500
Diagnostics
Software Version
[ Software Revision Level ]
Accelerometer
[ data ]
Over Amps
[ data, data ]
DC Volts
[ data ]
Internal Temperature
[ data ] °C
Security
Keypad Lock
[
Unlocked
, Amplitude Only, Locked ]
Security Code
[ 000 to 999 ]
Defaults
Restore Settings 1
[ ‘Enter’ Restores User Settings 1 ]
Restore Settings 2
[ ‘Enter’ Restores User Settings 2 ]
Restore Settings 3
[ ‘Enter’ Restores User Settings 3 ]
Save Settings 1
[ ‘Enter’ Saves User Settings 1 ]
Save Settings 2
[ ‘Enter’ Saves User Settings 2]
Save Settings 3
[ ‘Enter’ Saves User Settings 3]
Factory Reset
[ ‘Enter’ Resets Control to Factory Default Settings (Shown in
bold
) ]
Language
Pick Language
[ English, Spanish, French, German ]
The normal operating display shows the status of the control with regard to input signals and control settings. They are listed from highest to
lowest in priority. The highest priority message takes precedence over all other messages.
Stop/Run
- The Power button has been pushed to disable control operation.
Override
- The Power button has been pushed and held so the control will feed without interruption from the “Sensor” or “Run” inputs.
Run Input
- The run jumper has not been made.
Zero Speed
- The output is off because the output is set to 0.0%.
Run
- The feeder is running normally.
Run/CFR
- Constant Feed Rate sensor is regulating the feed rate (Autotune
®
).
Ma
in
Me
n
u
Normal Operation Display
Press and hold ‘Enter’ to enter the program menu or get the security menu.
Use the arrow up and down keys to adjust the security number. Press enter to test the security number.
Normal Display Message Priority
Gun/CFR
CFR=024.5
A= 40.0%
F= 60.0 Hz
R = 1
S = 1
O = 1
A = 1
Run Input: 1=on/closed & 0=off/open
Sensor input: 1=on/closed & 0=off/open
Output to vibratory feeder: 1=on & 0=off (Not used on G-Flex 1500)
Aux Output: 1=on & 0=off (Not used on G-Flex 1500)
Status Line Message
CFR Set Point
Amplitude
Frequency