The version is carried out with 38,400 bauds, 8 bits and even parity until it is ended by
a keystroke. A reset is triggered after the keystroke and the antenna is again in the nor-
mal mode (not monitor mode) with the stored parameters.
E.g. the CSV version can be stored (also see section 5.1 on page 33) by use of the
program hyper-terminal ®. Therefore, use the function record text in the menu trans-
mission ... and enter a file name (it should sensibly have the file ending .csv so that the
spreadsheet analysis recognizes the file by itself later) use. After the file has been re-
corded and closed under HyperTerminal®, it can be integrated into a spreadsheet cal-
cuation (e.g. Microsoft ® Excel ®, Sun ® StarCalc ®, ...) .
When opening the file, the spreadsheet analysis questions on some options. When
asked, answer that the values are separated by comma. The data can be processed
then into diagrammatic form or saved as a native spreadsheet analysis file for the
passing on.
5.2.2.10 (P)assword
Under password, the already known combination
815
can be used for saving the user
parameters or for the software update. Furthermore a new service password for device
specfific changes can be created.
5.2.2.11 Se(t)up Ref.transponder Values
Since the antennas aren't bound to one of certain end worth ones, this menu item was
introduced. The setup of the reference transponder should be executed one time at
the putting into operation and at a change of the interpreter.
NOTE!
This command should be only executed once during the putting
into operation since otherwise changes in the antenna precision
cannot be noticed since they are included in the reference val-
ues at every setup of the reference transponder!
The reference transponder is switched after starting of the reference transponder set-
up and the sum- and differential voltages are stored temporarily and shown on the
monitor program. To integrate those values, you must save them .
5.2.2.12 (U)pdate Firmware
The update sets the processor of the interpreter to the boot load mode. This boot load
offers the possibility the proceed a software update without disconnecting and then
connecting the device to the power supply. Therefore, the update program has to be
installed like described in chapter 5.3 on page 47.
Push
in the main menu. Then proceed the following steps:
1.
Open the flash program.
2.
Choose the COM port to which the antenna is connected.
3.
Choose the HEX file, which you want to program.
4.
Go back to Hyperterm und press any key.