Software
English, Revision 02, Date: 12.07.2011
43
-
: the autorun mode is (de)activated.
When the autorun function is deactivated, only the heartbeat message (when active)
is sent, the device is in the "preoperational" mode.
If autorun is active, the PDO and eartbeat message (if active) aer sent immediately af-
ter turning on. The device is in "operational" mode.
-
: the order of the bytes in TPDO can be altered here.
ERR LED
•
Previous function
Is lit when the error bits DEC_HW_ERR, PARAM_ERR, ANTENNA_ERROR are set and
when the reference transponder test was not successful.
•
Additional function
-
lit when permanent CAN bus error occurs (BUS offline)
-
blinks slowly in mode preoperational
-
blinks fast in mode stopp
5.2.2.6
CAN Terminator
On the board of the interpreter a 120 Ohm terminating resistor is designated. It can be
activated by a jumper.
Figure 19
Jumper of terminator on the board of the interpreter
Jumper for activating the terminator